Design of an optical passive semi-athermalization zoom lens | |
Yan, Aqi1,2![]() ![]() ![]() | |
作者部门 | 飞行器光学成像与测量技术研究室 |
2024-05-01 | |
发表期刊 | Applied Optics
![]() |
ISSN | 1559128X;21553165 |
卷号 | 63期号:13页码:3479-3488 |
产权排序 | 1 |
摘要 | Traditional zoom lenses cannot clearly image during the entire zoom process when the ambient temperature changes and needs to focus frequently at middle focal length positions. An innovative design method called the optical passive semi-athermalization (OPSA) design for zoom optical systems is proposed which, based on the difference in the focusing sensitivity of the focusing group at short and long focal length positions, seeks out sensitive groups that have a greater impact on the imaging quality at the short focal position. By changing the temperature characteristics of the temperature-sensitive lenses in these groups, an OPSA zoom optical system can be realized, which exhibits a compact structure and excellent imaging quality. Under the ambient temperature of −40◦C to +60◦C, the OPSA zoom lens needs to refocus only once at the long focal length position, which can ensure an image clearly during the entire zoom process. Remarkably, this innovative method not only mitigates the frequent focusing challenges in traditional zoom lenses, but also contributes to the diminutive size. © 2024 Optica Publishing Group (formerly OSA). All rights reserved. |
DOI | 10.1364/AO.517025 |
收录类别 | SCI ; EI |
语种 | 英语 |
WOS记录号 | WOS:001236681000001 |
出版者 | Optica Publishing Group (formerly OSA) |
EI入藏号 | 20242016084730 |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | http://ir.opt.ac.cn/handle/181661/97490 |
专题 | 飞行器光学成像与测量技术研究室 |
作者单位 | 1.Xi’an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Shaanxi, Xi’an; 710119, China; 2.Xi’an Key Laboratory of Aircraft Optical Imaging and Measurement Technology, Shaanxi, Xi’an; 710119, China; 3.University of Chinese Academy of Sciences, Beijing; 100049, China |
推荐引用方式 GB/T 7714 | Yan, Aqi,Chen, Weining,Li, Qianxi,et al. Design of an optical passive semi-athermalization zoom lens[J]. Applied Optics,2024,63(13):3479-3488. |
APA | Yan, Aqi,Chen, Weining,Li, Qianxi,Guo, Min,&Wang, Hao.(2024).Design of an optical passive semi-athermalization zoom lens.Applied Optics,63(13),3479-3488. |
MLA | Yan, Aqi,et al."Design of an optical passive semi-athermalization zoom lens".Applied Optics 63.13(2024):3479-3488. |