OPT OpenIR  > 光电跟踪与测量技术研究室
Auto-Alignment Non-Contact Optical Measurement Method for Quantifying Wobble Error of a Theodolite on a Vehicle-Mounted Platform
Li, Xiangyu1,2,3; Hao, Wei1,3; Xie, Meilin1,3; Liu, Bo1,3; Jiang, Bo1,3; Lv, Tao1,2,3; Song, Wei1,2,3; Ruan, Ping1,3
作者部门光电跟踪与测量技术研究室
2024
发表期刊Tehnicki Vjesnik
ISSN13303651;18486339
卷号31期号:2页码:449-459
产权排序1
摘要

During non-landing measurements of a theodolite, the accuracy of the goniometric readings can be compromised by wobble errors induced by various factors such as wind loads, theodolite driving torque, and the stiffness of the supporting structure. To achieve high-precision non-landing measurements, it is essential to accurately determine and correct the platform wobble errors affecting the azimuth and pitch pointing angles. In this paper, a non-contact optical measurement method is proposed for quantifying platform wobble errors. The method establishes an auto-alignment optical path between an autocollimator and a reflector in the measuring device. By detecting the deviation angle of the CCD image point as the optical path changes, precise measurements of the platform wobble errors can be obtained. Experimental results demonstrate that the measuring device can achieve an auto-alignment optical path within 5 minutes, significantly improving measurement efficiency. Furthermore, after measuring the platform wobble error and applying data correction, the average error in the azimuth pointing angle is reduced from 31.5″ to 9.8″, and the average error in the pitch pointing angle is reduced from 21″ to 9.2″. These results highlight the substantial correction effect achieved by the proposed method. © 2024, Strojarski Facultet. All rights reserved.

关键词autocollimator dual-axis inclinometer electro-optical theodolite optical measurement vehicle-mounted platform wobble error
DOI10.17559/TV-20230510000617
收录类别EI
语种英语
出版者Strojarski Facultet
EI入藏号20241115717961
引用统计
文献类型期刊论文
条目标识符http://ir.opt.ac.cn/handle/181661/97276
专题光电跟踪与测量技术研究室
通讯作者Ruan, Ping
作者单位1.Key Laboratory of Space Precision Measurement Technology, Xi’an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi’an; 710119, China;
2.University of Chinese Academy of Sciences, Beijing; 100049, China;
3.Xi'an Hi-Tech Industrial Development Zone, NO.17 Xinxi Road, New Industrial Park, Shaanxi, Xi'an; 710119, China
推荐引用方式
GB/T 7714
Li, Xiangyu,Hao, Wei,Xie, Meilin,et al. Auto-Alignment Non-Contact Optical Measurement Method for Quantifying Wobble Error of a Theodolite on a Vehicle-Mounted Platform[J]. Tehnicki Vjesnik,2024,31(2):449-459.
APA Li, Xiangyu.,Hao, Wei.,Xie, Meilin.,Liu, Bo.,Jiang, Bo.,...&Ruan, Ping.(2024).Auto-Alignment Non-Contact Optical Measurement Method for Quantifying Wobble Error of a Theodolite on a Vehicle-Mounted Platform.Tehnicki Vjesnik,31(2),449-459.
MLA Li, Xiangyu,et al."Auto-Alignment Non-Contact Optical Measurement Method for Quantifying Wobble Error of a Theodolite on a Vehicle-Mounted Platform".Tehnicki Vjesnik 31.2(2024):449-459.
条目包含的文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Auto-Alignment Non-C(1574KB)期刊论文出版稿限制开放CC BY-NC-SA请求全文
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Li, Xiangyu]的文章
[Hao, Wei]的文章
[Xie, Meilin]的文章
百度学术
百度学术中相似的文章
[Li, Xiangyu]的文章
[Hao, Wei]的文章
[Xie, Meilin]的文章
必应学术
必应学术中相似的文章
[Li, Xiangyu]的文章
[Hao, Wei]的文章
[Xie, Meilin]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。