Optimization of polarization parameters for an LCVR polarization spectrometer under non-oversampling
Chang, Lingying1; Wang, Guanru1; Wang, Xinyou1; Qiu, Yuehong2; Chen, Kui1; Liang, Chi1
作者部门空间光学技术研究室
2023-06-01
发表期刊APPLIED OPTICS
ISSN1559-128X;2155-3165
卷号62期号:16页码:4150–4160
产权排序2
摘要

The spectral polarization measurement can obtain not only the spectral information of the target but also its polari-zation information, which can improve the detection and identification of the measured target. In the polarization spectrometer based on a liquid crystal variable retarder (LCVR) and acousto-optic tunable filter (AOTF), the LCVR is a core device for achieving fast and high-precision polarization detection. The AOTF is a new, to the best of our knowledge, filter device for spectral tuning. To reduce the sensitivity of an LCVR-based Stokes polarization spec-trometer system to errors and Gaussian noise, and to maintain the advantage of fast electrical tuning of the system for spectral polarization detection, the phase retardation and azimuth angle of the polarization device LCVR is calculated and analyzed optimally under the minimum number of samples N = 4 of the Stokes vector measurement method in this paper. The optimization algorithm considers the constraints, such as the number of types of LCVR phase retardation and the number of adjustments, and the azimuth and phase retardation to be optimized are searched for optimality step by step. The simulation results show that the number of adjustments of the phase retar-dation & delta; of LCVRs is only three times when four Stokes parameters are obtained. The LCVRs' number of species is four kinds (2 x 2). The condition number of the optimized measurement matrix is 1.742, which converges to the ideal condition number, the optimal azimuth angle (& theta;1, & theta;2) is (18.9 & DEG;, 41.9 & DEG;), and the optimal phase retardation & delta; is (179.9 & DEG;, 156.6 & DEG;, 0.4 & DEG;, 46.3 & DEG;). Its corresponding tetrahedral volume is closer to the ideal value. The optimized system is less sensitive to errors and Gaussian noise.& COPY; 2023 Optica Publishing Group

DOI10.1364/AO.486941
收录类别SCI
语种英语
WOS记录号WOS:001012338700003
出版者Optica Publishing Group
引用统计
被引频次:1[WOS]   [WOS记录]     [WOS相关记录]
文献类型期刊论文
条目标识符http://ir.opt.ac.cn/handle/181661/96659
专题空间光学技术研究室
通讯作者Chang, Lingying
作者单位1.Xian Univ Posts & Telecommun, Sch Elect Engn, Xian 710121, Peoples R China
2.Chinese Acad Sci, Xian Inst Opt & Precis Mech, Xian 710119, Peoples R China
推荐引用方式
GB/T 7714
Chang, Lingying,Wang, Guanru,Wang, Xinyou,et al. Optimization of polarization parameters for an LCVR polarization spectrometer under non-oversampling[J]. APPLIED OPTICS,2023,62(16):4150–4160.
APA Chang, Lingying,Wang, Guanru,Wang, Xinyou,Qiu, Yuehong,Chen, Kui,&Liang, Chi.(2023).Optimization of polarization parameters for an LCVR polarization spectrometer under non-oversampling.APPLIED OPTICS,62(16),4150–4160.
MLA Chang, Lingying,et al."Optimization of polarization parameters for an LCVR polarization spectrometer under non-oversampling".APPLIED OPTICS 62.16(2023):4150–4160.
条目包含的文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Optimization of pola(29441KB)期刊论文出版稿限制开放CC BY-NC-SA请求全文
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Chang, Lingying]的文章
[Wang, Guanru]的文章
[Wang, Xinyou]的文章
百度学术
百度学术中相似的文章
[Chang, Lingying]的文章
[Wang, Guanru]的文章
[Wang, Xinyou]的文章
必应学术
必应学术中相似的文章
[Chang, Lingying]的文章
[Wang, Guanru]的文章
[Wang, Xinyou]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。