Optimization of polarization parameters for an LCVR polarization spectrometer under non-oversampling | |
Chang, Lingying1![]() ![]() | |
作者部门 | 空间光学技术研究室 |
2023-06-01 | |
发表期刊 | APPLIED OPTICS
![]() |
ISSN | 1559-128X;2155-3165 |
卷号 | 62期号:16页码:4150–4160 |
产权排序 | 2 |
摘要 | The spectral polarization measurement can obtain not only the spectral information of the target but also its polari-zation information, which can improve the detection and identification of the measured target. In the polarization spectrometer based on a liquid crystal variable retarder (LCVR) and acousto-optic tunable filter (AOTF), the LCVR is a core device for achieving fast and high-precision polarization detection. The AOTF is a new, to the best of our knowledge, filter device for spectral tuning. To reduce the sensitivity of an LCVR-based Stokes polarization spec-trometer system to errors and Gaussian noise, and to maintain the advantage of fast electrical tuning of the system for spectral polarization detection, the phase retardation and azimuth angle of the polarization device LCVR is calculated and analyzed optimally under the minimum number of samples N = 4 of the Stokes vector measurement method in this paper. The optimization algorithm considers the constraints, such as the number of types of LCVR phase retardation and the number of adjustments, and the azimuth and phase retardation to be optimized are searched for optimality step by step. The simulation results show that the number of adjustments of the phase retar-dation & delta; of LCVRs is only three times when four Stokes parameters are obtained. The LCVRs' number of species is four kinds (2 x 2). The condition number of the optimized measurement matrix is 1.742, which converges to the ideal condition number, the optimal azimuth angle (& theta;1, & theta;2) is (18.9 & DEG;, 41.9 & DEG;), and the optimal phase retardation & delta; is (179.9 & DEG;, 156.6 & DEG;, 0.4 & DEG;, 46.3 & DEG;). Its corresponding tetrahedral volume is closer to the ideal value. The optimized system is less sensitive to errors and Gaussian noise.& COPY; 2023 Optica Publishing Group |
DOI | 10.1364/AO.486941 |
收录类别 | SCI ; EI |
语种 | 英语 |
WOS记录号 | WOS:001012338700003 |
出版者 | Optica Publishing Group |
EI入藏号 | 20232514254024 |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | http://ir.opt.ac.cn/handle/181661/96659 |
专题 | 空间光学技术研究室 |
通讯作者 | Chang, Lingying |
作者单位 | 1.Xian Univ Posts & Telecommun, Sch Elect Engn, Xian 710121, Peoples R China 2.Chinese Acad Sci, Xian Inst Opt & Precis Mech, Xian 710119, Peoples R China |
推荐引用方式 GB/T 7714 | Chang, Lingying,Wang, Guanru,Wang, Xinyou,et al. Optimization of polarization parameters for an LCVR polarization spectrometer under non-oversampling[J]. APPLIED OPTICS,2023,62(16):4150–4160. |
APA | Chang, Lingying,Wang, Guanru,Wang, Xinyou,Qiu, Yuehong,Chen, Kui,&Liang, Chi.(2023).Optimization of polarization parameters for an LCVR polarization spectrometer under non-oversampling.APPLIED OPTICS,62(16),4150–4160. |
MLA | Chang, Lingying,et al."Optimization of polarization parameters for an LCVR polarization spectrometer under non-oversampling".APPLIED OPTICS 62.16(2023):4150–4160. |
条目包含的文件 | ||||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | ||
Optimization of pola(29441KB) | 期刊论文 | 出版稿 | 限制开放 | CC BY-NC-SA | 请求全文 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论