Extended field of view of light-sheet fluorescence microscopy by scanning multiple focus-shifted Gaussian beam arrays | |
Liu, Chao1,2; Bai, Chen1; Yu, Xianghua1; Yan, Shaohui1; Zhou, Yuan1,2; Li, Xing1,2; Min, Junwei1![]() ![]() ![]() ![]() | |
作者部门 | 瞬态光学研究室 |
2021-02-15 | |
发表期刊 | Optics Express
![]() |
ISSN | 10944087 |
卷号 | 29期号:4页码:6158-6168 |
产权排序 | 1 |
摘要 | Light-sheet fluorescence microscopy (LSFM) facilitates high temporal-spatial resolution, low photobleaching and phototoxicity for long-term volumetric imaging. However, when a high axial resolution or optical sectioning capability is required, the field of view (FOV) is limited. Here, we propose to generate a large FOV of light-sheet by scanning multiple focus-shifted Gaussian beam arrays (MGBA) while keeping the high axial resolution. The positions of the beam waists of the multiple Gaussian beam arrays are shifted in both axial and lateral directions in an optimized arranged pattern, and then scanned along the direction perpendicular to the propagation axis to form an extended FOV of light-sheet. Complementary beam subtraction method is also adopted to further improve axial resolution. Compared with the single Gaussian light-sheet method, the proposed method extends the FOV from 12 µm to 200 µm while sustaining the axial resolution of 0.73 µm. Both numerical simulation and experiment on samples are performed to verify the effectiveness of the method. © 2021 Optical Society of America under the terms of the OSA Open Access Publishing Agreement |
DOI | 10.1364/OE.418707 |
收录类别 | SCI ; EI |
语种 | 英语 |
WOS记录号 | WOS:000619209800120 |
出版者 | OSA - The Optical Society |
EI入藏号 | 20210809951158 |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | http://ir.opt.ac.cn/handle/181661/94442 |
专题 | 瞬态光学研究室 |
作者单位 | 1.State Key Laboratory of Transient Optics and Photonics, Xi’an Institute of Optics and PrecisionMechanics, Chinese Academy of Sciences, Xi’an, Shaanxi; 710119, China; 2.University of Chinese Academy of Sciences, Beijing; 100049, China |
推荐引用方式 GB/T 7714 | Liu, Chao,Bai, Chen,Yu, Xianghua,et al. Extended field of view of light-sheet fluorescence microscopy by scanning multiple focus-shifted Gaussian beam arrays[J]. Optics Express,2021,29(4):6158-6168. |
APA | Liu, Chao.,Bai, Chen.,Yu, Xianghua.,Yan, Shaohui.,Zhou, Yuan.,...&Yao, Baoli.(2021).Extended field of view of light-sheet fluorescence microscopy by scanning multiple focus-shifted Gaussian beam arrays.Optics Express,29(4),6158-6168. |
MLA | Liu, Chao,et al."Extended field of view of light-sheet fluorescence microscopy by scanning multiple focus-shifted Gaussian beam arrays".Optics Express 29.4(2021):6158-6168. |
条目包含的文件 | ||||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | ||
Extended field of vi(5927KB) | 期刊论文 | 出版稿 | 限制开放 | CC BY-NC-SA | 请求全文 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论