Using Cherenkov imaging to monitor the match line between photon and electron radiation therapy fields on biological tissue phantoms
Li, Yi1,2,3; Liu, Hongjun1,4; Huang, Nan1; Wang, Zhaolu1; Zhang, Chunmin2
作者部门瞬态光学研究室
2020-12-01
发表期刊Journal of Biomedical Optics
ISSN10833668;15602281
卷号25期号:12
产权排序1
摘要

Significance: Due to patients' respiratory movement or involuntary body movements during breast cancer radiotherapy, the mismatched adjacent fields in surface exposure regions could result in insufficient dosage or overdose in these regions, which would lead to tissue injury, excessive skin burns, and potential death. Cherenkov luminescence imaging (CLI) could be used to effectively detect the matching information of adjacent radiation fields without extra radiation or invasive imaging. Aim: Our objective was to provide a biological experimental basis for monitoring matching of adjacent radiation fields between photon and electron fields due to introduced shifts during radiotherapy by CLI technique. Approach: A medical accelerator was used to generate photon and electron fields. An industrial camera system was adopted to image the excited CLI signal during irradiation of chicken tissue with yellow (group A and group C experiments) or black color (group B experiment). The following introduced shifts were tested: 10, 5, 2, and 0 mm toward superior or inferior direction. A model was introduced to deal with matching error analysis of adjacent radiation fields due to introduced shifts with adapted plans used to treat neoplasms of the right breast with supraclavicular nodes or internal mammary lymph node. Results: The matching values between photon and electron fields were consistent with the tested introduced shifts during yellow chicken irradiation. In group A, average discrepancies were 0.59 ± 0.35 mm and 0.68 ± 0.37 mm for photon fields and electron fields in anterior/posterior (AP) direction, with 87% and 75% of measurement within 1 mm, respectively. In group C, average discrepancies were 0.80 ± 0.65 mm and 1.07 ± 0.57 mm for oblique photon field with gantry angles of 330 deg and 150 deg, with 66% and 65% of measurement within 1 mm, respectively. The average discrepancies were 0.44 ± 0.30 mm for electron field in the AP direction, with 94% of measurement within 1 mm. The matching error introduced by the proposed method was less than 1.5 mm for AP fields and 2 mm for oblique incidence fields. However, the field matching could not be monitored with black chicken tissue irradiation due to a weak CLI signal that could hardly be extracted from background noise in group B. Conclusions: CLI is demonstrated for the quantitative monitoring of the field match line on light biological tissue phantoms and has potential for monitoring of field matching in surface tissue during breast cancer radiotherapy. © The Authors. Published by SPIE under a Creative Commons Attribution 4.0 Unported License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its.

关键词Cherenkov luminescence imaging radiotherapy field matching biological tissue charge-coupled device
DOI10.1117/1.JBO.25.12.125001
收录类别SCI ; EI
语种英语
WOS记录号WOS:000605144900009
出版者SPIE
EI入藏号20210109729092
引用统计
被引频次:3[WOS]   [WOS记录]     [WOS相关记录]
文献类型期刊论文
条目标识符http://ir.opt.ac.cn/handle/181661/94241
专题瞬态光学研究室
通讯作者Liu, Hongjun; Zhang, Chunmin
作者单位1.Chinese Academy of Sciences, Xi'An Institute of Optics and Precision Mechanics, State Key Laboratory of Transient Optics and Photonics, Xi'an, China;
2.Xi'An Jiaotong University, School of Physics, Xi'an, China;
3.University of Chinese Academy of Sciences, Beijing, China;
4.Shanxi University, Collaborative Innovation Center of Extreme Optics, Taiyuan, China
推荐引用方式
GB/T 7714
Li, Yi,Liu, Hongjun,Huang, Nan,et al. Using Cherenkov imaging to monitor the match line between photon and electron radiation therapy fields on biological tissue phantoms[J]. Journal of Biomedical Optics,2020,25(12).
APA Li, Yi,Liu, Hongjun,Huang, Nan,Wang, Zhaolu,&Zhang, Chunmin.(2020).Using Cherenkov imaging to monitor the match line between photon and electron radiation therapy fields on biological tissue phantoms.Journal of Biomedical Optics,25(12).
MLA Li, Yi,et al."Using Cherenkov imaging to monitor the match line between photon and electron radiation therapy fields on biological tissue phantoms".Journal of Biomedical Optics 25.12(2020).
条目包含的文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Using Cherenkov imag(3669KB)期刊论文出版稿限制开放CC BY-NC-SA请求全文
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Li, Yi]的文章
[Liu, Hongjun]的文章
[Huang, Nan]的文章
百度学术
百度学术中相似的文章
[Li, Yi]的文章
[Liu, Hongjun]的文章
[Huang, Nan]的文章
必应学术
必应学术中相似的文章
[Li, Yi]的文章
[Liu, Hongjun]的文章
[Huang, Nan]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。