OPT OpenIR  > 瞬态光学研究室
Long modal interference in multimode fiber and its application in vital signs monitoring
Xu, Wei1,2; Shen, Ying3; Yu, Changyuan4; Dong, Bo1,2,5; Zhao, Wei1,2,5; Wang, Yishan1,2,5
作者部门瞬态光学研究室
2020-11-01
发表期刊Optics Communications
ISSN00304018
卷号474
产权排序1
摘要

All-fiber vital signs monitoring based on long-modal-interference (LMI) in multimode fiber (MMF) is proposed and investigated theoretically and experimentally. The LMI-MMF is simply formed by splicing of a two-meter-long MMF and two single mode fibers (SMFs) with core-offsets at splicing joints. It is worth mentioning that all fibers that used are sheathed with 900-μm protection sleeve. Core-offset dependency of vital signs monitoring performance is specifically analyzed. Experiments are carried out on subjects with weight from 56 kg to 103 kg without further optimization or modification. Compared with commercial piezoceramic-based respiratory sensor and SpO2-based heartbeat sensor, the proposed non-wearable all-fiber vital signs monitoring sensor based on LMI-MMF shows great consistence with high Person's correlation coefficient. It is the first time to put forward the LMI-MMF-based fiber sensor and apply it to realize the non-wearable vital signs monitoring. Specific superiorities of low cost, real time and non-intrusiveness make it potentially competitive in household healthcare and other medical fields. © 2020 Elsevier B.V.

关键词All-fiber Vital signs monitoring Long modal interference
DOI10.1016/j.optcom.2020.126100
收录类别SCI ; EI
语种英语
WOS记录号WOS:000579424200049
出版者Elsevier B.V.
EI入藏号20202208759915
引用统计
被引频次:9[WOS]   [WOS记录]     [WOS相关记录]
文献类型期刊论文
条目标识符http://ir.opt.ac.cn/handle/181661/93466
专题瞬态光学研究室
通讯作者Dong, Bo
作者单位1.State Key Laboratory of Transient Optics and Photonics, Xi'an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi'an; 710119, China;
2.University of Chinese Academy of Sciences, Beijing; 100049, China;
3.School of Electronic & Information Engineering, Soochow University, 215006, China;
4.Department of Electronic and Information Engineering, The Hong Kong Polytechnic University, Hong Kong;
5.Collaborative Innovation Center of Extreme Optics Shanxi University, Taiyuan; 030006, China
推荐引用方式
GB/T 7714
Xu, Wei,Shen, Ying,Yu, Changyuan,et al. Long modal interference in multimode fiber and its application in vital signs monitoring[J]. Optics Communications,2020,474.
APA Xu, Wei,Shen, Ying,Yu, Changyuan,Dong, Bo,Zhao, Wei,&Wang, Yishan.(2020).Long modal interference in multimode fiber and its application in vital signs monitoring.Optics Communications,474.
MLA Xu, Wei,et al."Long modal interference in multimode fiber and its application in vital signs monitoring".Optics Communications 474(2020).
条目包含的文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Long modal interfere(5754KB)期刊论文出版稿限制开放CC BY-NC-SA请求全文
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Xu, Wei]的文章
[Shen, Ying]的文章
[Yu, Changyuan]的文章
百度学术
百度学术中相似的文章
[Xu, Wei]的文章
[Shen, Ying]的文章
[Yu, Changyuan]的文章
必应学术
必应学术中相似的文章
[Xu, Wei]的文章
[Shen, Ying]的文章
[Yu, Changyuan]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。