Long modal interference in multimode fiber and its application in vital signs monitoring | |
Xu, Wei1,2![]() ![]() ![]() | |
作者部门 | 瞬态光学研究室 |
2020-11-01 | |
发表期刊 | Optics Communications
![]() |
ISSN | 00304018 |
卷号 | 474 |
产权排序 | 1 |
摘要 | All-fiber vital signs monitoring based on long-modal-interference (LMI) in multimode fiber (MMF) is proposed and investigated theoretically and experimentally. The LMI-MMF is simply formed by splicing of a two-meter-long MMF and two single mode fibers (SMFs) with core-offsets at splicing joints. It is worth mentioning that all fibers that used are sheathed with 900-μm protection sleeve. Core-offset dependency of vital signs monitoring performance is specifically analyzed. Experiments are carried out on subjects with weight from 56 kg to 103 kg without further optimization or modification. Compared with commercial piezoceramic-based respiratory sensor and SpO2-based heartbeat sensor, the proposed non-wearable all-fiber vital signs monitoring sensor based on LMI-MMF shows great consistence with high Person's correlation coefficient. It is the first time to put forward the LMI-MMF-based fiber sensor and apply it to realize the non-wearable vital signs monitoring. Specific superiorities of low cost, real time and non-intrusiveness make it potentially competitive in household healthcare and other medical fields. © 2020 Elsevier B.V. |
关键词 | All-fiber Vital signs monitoring Long modal interference |
DOI | 10.1016/j.optcom.2020.126100 |
收录类别 | SCI ; EI |
语种 | 英语 |
WOS记录号 | WOS:000579424200049 |
出版者 | Elsevier B.V. |
EI入藏号 | 20202208759915 |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | http://ir.opt.ac.cn/handle/181661/93466 |
专题 | 瞬态光学研究室 |
通讯作者 | Dong, Bo |
作者单位 | 1.State Key Laboratory of Transient Optics and Photonics, Xi'an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi'an; 710119, China; 2.University of Chinese Academy of Sciences, Beijing; 100049, China; 3.School of Electronic & Information Engineering, Soochow University, 215006, China; 4.Department of Electronic and Information Engineering, The Hong Kong Polytechnic University, Hong Kong; 5.Collaborative Innovation Center of Extreme Optics Shanxi University, Taiyuan; 030006, China |
推荐引用方式 GB/T 7714 | Xu, Wei,Shen, Ying,Yu, Changyuan,et al. Long modal interference in multimode fiber and its application in vital signs monitoring[J]. Optics Communications,2020,474. |
APA | Xu, Wei,Shen, Ying,Yu, Changyuan,Dong, Bo,Zhao, Wei,&Wang, Yishan.(2020).Long modal interference in multimode fiber and its application in vital signs monitoring.Optics Communications,474. |
MLA | Xu, Wei,et al."Long modal interference in multimode fiber and its application in vital signs monitoring".Optics Communications 474(2020). |
条目包含的文件 | ||||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | ||
Long modal interfere(5754KB) | 期刊论文 | 出版稿 | 限制开放 | CC BY-NC-SA | 请求全文 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。