Scintillation crystals of 20 mm length or longer are needed for clinical time-of-flight positron emission tomography (TOF-PET) to ensure effective detection efficiency for gamma photons. However, the use of long crystals would deteriorate the key performance of TOF-PET detectors, time and spatial resolution, because of the variations in the travel times of the photons in crystals and the effects of parallax errors. In this work, we studied double-ended readout TOF-PET detectors based on coupling a long scintillation crystal to SiPMs at both ends for correcting the depth-dependent effects to improve the coincidence time resolution (CTR). In particular, we focused our attention to analyze timing performance using different correction methods, including trigger times of the individual photodetectors at both ends of the crystal, the simple average of the trigger times, and the weighted average based on the inverse variances of the depth-dependent corrected trigger times. For a 3 mm × 3 mm × 25 mm unpolished lutetium fine silicate (LFS) crystal with double-ended readout and practical head-on irradiation, a CTR of 246 ps FWHM can be achieved using depth-dependent timing-correction and weighted average time method compared to 280 ps FWHM using the conventional simple average time method and 393 ps FWHM using the conventional single-ended readout. The results show that the depth-dependent timing-correction and weighted average time method in double-ended readout can effectively correct for the trigger time variations in TOF-PET detector utilizing long unpolished crystals, resulting in an improvement in the CTR of as much as 37% compared to single-ended readout. © 2020 IOP Publishing Ltd and Sissa Medialab.

关键词Gamma camera SPECT PET PET/CT coronary CT angiography (CTA) Instrumentationfor gamma-electron therapy
DOI10.1088/1748-0221/15/01/P01003
收录类别SCI ; EI
语种英语
WOS记录号WOS:000525449600003
出版者Institute of Physics Publishing
EI入藏号20201208314004
引用统计
被引频次:10[WOS]   [WOS记录]     [WOS相关记录]
文献类型期刊论文
条目标识符http://ir.opt.ac.cn/handle/181661/93324
专题条纹相机工程中心
作者单位1.Molecular Biophysics and Integrated Bioimaging Division, Lawrence Berkeley National Laboratory, 1 Cyclotron Road, Berkeley; CA; 94720, United States;
2.Key Laboratory of Ultra-fast Photoelectric Diagnostics Technology, Xi'An Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, No. 17 Xinxi Road, Xi'an; 710119, China;
3.College of Materials Science and Opto-Electronic Technology, University of Chinese Academy of Sciences, No. 19 Yuquan Road, Beijing; 100049, China;
4.Collaborative Innovation Center of Extreme Optics, Shanxi University, No. 92 Wucheng Road, Taiyuan; 030006, China
推荐引用方式
GB/T 7714
Guo, L.,Tian, J.,Chen, P.,et al. Improving timing performance of double-ended readout in TOF-PET detectors[J]. Journal of Instrumentation,2020,15(1).
APA Guo, L.,Tian, J.,Chen, P.,Derenzo, S.E.,&Choong, W.-S..(2020).Improving timing performance of double-ended readout in TOF-PET detectors.Journal of Instrumentation,15(1).
MLA Guo, L.,et al."Improving timing performance of double-ended readout in TOF-PET detectors".Journal of Instrumentation 15.1(2020).
条目包含的文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Improving timing per(2376KB)期刊论文出版稿开放获取CC BY-NC-SA浏览 请求全文
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Guo, L.]的文章
[Tian, J.]的文章
[Chen, P.]的文章
百度学术
百度学术中相似的文章
[Guo, L.]的文章
[Tian, J.]的文章
[Chen, P.]的文章
必应学术
必应学术中相似的文章
[Guo, L.]的文章
[Tian, J.]的文章
[Chen, P.]的文章
相关权益政策
暂无数据
收藏/分享
文件名: Improving timing performance of double-ended readout in TOF-PET detectors.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。