Xi'an Institute of Optics and Precision Mechanics,CAS
Simulation of microchannel plate photomultiplier tube in high magnetic fields | |
Chen, Ping1,2,3,4,5; Yuan, Xiaohui1,2,3; Tian, Jinshou4,5![]() ![]() ![]() ![]() ![]() | |
作者部门 | 条纹相机工程中心 |
2019-08-21 | |
发表期刊 | NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT
![]() |
ISSN | 0168-9002;1872-9576 |
卷号 | 936页码:580-582 |
产权排序 | 1 |
摘要 | The microchannel plate photomultiplier tube (MCP-PMT) used in high energy physics experiments usually needs to be able to operate in strong magnetic fields. In this paper, a 3D MCP-PMT model is developed in CST studio suite to study the magnetic field up to 5 T effect on the photoelectrons traveling from the photocathode to the MCP. Results predict that a growing number of photoelectrons strike back to the photocathode with enhancing magnetic field, which not only decreases electron collection efficiency and gain, but also impairs the photocathode lifetime. |
关键词 | MCP-PMT Microchannel plate Collection efficiency Magnetic field |
DOI | 10.1016/j.nima.2018.10.088 |
收录类别 | SCI |
语种 | 英语 |
WOS记录号 | WOS:000471828100220 |
出版者 | ELSEVIER SCIENCE BV |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | http://ir.opt.ac.cn/handle/181661/31559 |
专题 | 条纹相机工程中心 |
通讯作者 | Chen, Ping |
作者单位 | 1.Shanghai Jiao Tong Univ, Minist Educ, Key Lab Laser Plasmas, Shanghai 200240, Peoples R China 2.Shanghai Jiao Tong Univ, Sch Phys & Astron, Shanghai 200240, Peoples R China 3.Shanghai Jiao Tong Univ, Collaborat Innovat Ctr IFSA CICIFSA, Shanghai 200240, Peoples R China 4.Chinese Acad Sci, XIOPM, Key Lab Ultrafast Photoelect Diagnost Technol, Xian 710119, Shaanxi, Peoples R China 5.Shanxi Univ, Collaborat Innovat Ctr Extreme Opt, Taiyuan 030006, Shanxi, Peoples R China |
推荐引用方式 GB/T 7714 | Chen, Ping,Yuan, Xiaohui,Tian, Jinshou,et al. Simulation of microchannel plate photomultiplier tube in high magnetic fields[J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT,2019,936:580-582. |
APA | Chen, Ping.,Yuan, Xiaohui.,Tian, Jinshou.,Wang, Xing.,Wen, Wenlong.,...&Zhao, Xu.(2019).Simulation of microchannel plate photomultiplier tube in high magnetic fields.NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT,936,580-582. |
MLA | Chen, Ping,et al."Simulation of microchannel plate photomultiplier tube in high magnetic fields".NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT 936(2019):580-582. |
条目包含的文件 | ||||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | ||
Simulation of microc(497KB) | 期刊论文 | 出版稿 | 开放获取 | CC BY-NC-SA | 浏览 请求全文 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论