Axial resolution enhancement of light-sheet microscopy by double scanning of Bessel beam and its complementary beam | |
Jia, Hao1,2; Yu, Xianghua1; Yang, Yanlong1![]() ![]() ![]() | |
作者部门 | 瞬态光学研究室 |
2019-01 | |
发表期刊 | JOURNAL OF BIOPHOTONICS
![]() |
ISSN | 1864-063X;1864-0648 |
卷号 | 12期号:1 |
产权排序 | 1 |
摘要 | The side lobes of Bessel beam will create significant out-of-focus background when scanned in light-sheet fluorescence microscopy (LSFM), limiting the axial resolution of the imaging system. Here, we propose to overcome this issue by scanning the sample twice with zeroth-order Bessel beam and another type of propagation-invariant beam, complementary to the zeroth-order Bessel beam, which greatly reduces the out-of-focus background created in the first scan. The axial resolution can be improved from 1.68 mu m of the Bessel light-sheet to 1.07 mu m by subtraction of the two scanned images across a whole field-of-view of up to 300 mu m x 200 mu m x 200 mu m. The optimization procedure to create the complementary beam is described in detail and it is experimentally generated with a spatial light modulator. The imaging performance is validated experimentally with fluorescent beads as well as eGFP-labeled mouse brain neurons. |
关键词 | Bessel beam laser beam shaping light-sheet fluorescence microscopy three-dimensional microscopy |
DOI | 10.1002/jbio.201800094 |
收录类别 | SCI |
语种 | 英语 |
WOS记录号 | WOS:000455115500018 |
出版者 | WILEY-V C H VERLAG GMBH |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | http://ir.opt.ac.cn/handle/181661/31181 |
专题 | 瞬态光学研究室 |
通讯作者 | Yao, Baoli |
作者单位 | 1.Chinese Acad Sci, Xian Inst Opt & Precis Mech, State Key Lab Transient Opt & Photon, Xian 710119, Shaanxi, Peoples R China 2.Univ Chinese Acad Sci, Sch Mat, Beijing 100049, Peoples R China |
推荐引用方式 GB/T 7714 | Jia, Hao,Yu, Xianghua,Yang, Yanlong,et al. Axial resolution enhancement of light-sheet microscopy by double scanning of Bessel beam and its complementary beam[J]. JOURNAL OF BIOPHOTONICS,2019,12(1). |
APA | Jia, Hao.,Yu, Xianghua.,Yang, Yanlong.,Zhou, Xing.,Yan, Shaohui.,...&Yao, Baoli.(2019).Axial resolution enhancement of light-sheet microscopy by double scanning of Bessel beam and its complementary beam.JOURNAL OF BIOPHOTONICS,12(1). |
MLA | Jia, Hao,et al."Axial resolution enhancement of light-sheet microscopy by double scanning of Bessel beam and its complementary beam".JOURNAL OF BIOPHOTONICS 12.1(2019). |
条目包含的文件 | ||||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | ||
Axial resolution enh(2113KB) | 期刊论文 | 出版稿 | 限制开放 | CC BY-NC-SA | 请求全文 |