Design of a control system with high stability for a streak camera using isolated ADC
作者: Fang, Yu-Man1,2; Xu, Xiang-Yan1; Tian, Jin-Shou1; Pei, Cheng-Quan3
作者部门: 精密物理量测量实验室
刊名: NUCLEAR SCIENCE AND TECHNIQUES
出版日期: 2018-02
卷号: 29, 期号:2
关键词: ICF ; Distributed control ; Streak camera ; Isolated ADC ; X-ray detector
学科分类: Nuclear Science & Technology ; Physics, Nuclear
DOI: 10.1007/s41365-018-0361-9
通讯作者: Xu, XY (reprint author), Xian Inst Opt & Precis Mech, Key Lab Ultrafast Photoelect Diagnost Technol, Xian 710119, Shaanxi, Peoples R China.
英文摘要:

The streak camera is an ultra-fast diagnostic instrument with high sensitivity, and a high temporal and spatial resolution. It is primarily employed in various scientific research, such as inertial confinement fusion (ICF), synchrotron light sources, and electron-positron colliders. An automatic control system for an X-ray streak camera is presented in this paper. The output terminal of an analog-to-digital converter was isolated from its input terminal, to reduce interference from high-voltage electrodes. Compared with traditional methods, this scheme also improved the internal electromagnetic interface immunity. Therefore, the system stability was enhanced. With this optimized control system, some characterizations of the streak camera were measured. Static and dynamic spatial resolutions of 25 and 20 lp/mm (CTF = 20%), respectively, were obtained. In addition, a dynamic range of 552:1 and a temporal resolution of 7.3 ps were achieved. The results confirmed that these characterizations are sufficient for the specifications derived from the diagnostic requirements of ICF.

研究领域[WOS]: Nuclear Science & Technology ; Physics
收录类别: SCI
语种: 英语
WOS记录号: WOS:000427326900006
ISSN号: 1001-8042
产权排序: 1
Citation statistics:
内容类型: 期刊论文
URI标识: http://ir.opt.ac.cn/handle/181661/30018
Appears in Collections:精密物理量测量实验室_期刊论文

Files in This Item:
File Name/ File Size Content Type Version Access License
Design of a control system with high stability for a streak camera using isolated ADC.pdf(2384KB)期刊论文作者接受稿开放获取View 联系获取全文

作者单位: 1.Xian Inst Opt & Precis Mech, Key Lab Ultrafast Photoelect Diagnost Technol, Xian 710119, Shaanxi, Peoples R China
2.Univ Chinese Acad Sci, Beijing 100049, Peoples R China
3.Xi An Jiao Tong Univ, Xian 710049, Shaanxi, Peoples R China

Recommended Citation:
Fang, Yu-Man,Xu, Xiang-Yan,Tian, Jin-Shou,et al. Design of a control system with high stability for a streak camera using isolated ADC[J]. NUCLEAR SCIENCE AND TECHNIQUES,2018-02-01,29(2).
Service
Recommend this item
Sava as my favorate item
Show this item's statistics
Export Endnote File
Google Scholar
Similar articles in Google Scholar
[Fang, Yu-Man]'s Articles
[Xu, Xiang-Yan]'s Articles
[Tian, Jin-Shou]'s Articles
CSDL cross search
Similar articles in CSDL Cross Search
[Fang, Yu-Man]‘s Articles
[Xu, Xiang-Yan]‘s Articles
[Tian, Jin-Shou]‘s Articles
Related Copyright Policies
Null
Social Bookmarking
Add to CiteULike Add to Connotea Add to Del.icio.us Add to Digg Add to Reddit
文件名: Design of a control system with high stability for a streak camera using isolated ADC.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 
评注功能仅针对注册用户开放,请您登录
您对该条目有什么异议,请填写以下表单,管理员会尽快联系您。
内 容:
Email:  *
单位:
验证码:   刷新
您在IR的使用过程中有什么好的想法或者建议可以反馈给我们。
标 题:
 *
内 容:
Email:  *
验证码:   刷新

Items in IR are protected by copyright, with all rights reserved, unless otherwise indicated.

 

 

Valid XHTML 1.0!
Powered by CSpace