摘要 | The structure and work principle of an ultraviolet photon counting imaging detector based on wedge and strip anode with induction readout mode are introduced. Two methods of estimating the charge footprint size are presented. One way is theoretical calculation and simulation. The physical course of electrons is simulated from the microchannel plate output side to the readout anode. The calculated results show that the final charge footprint size is sensitive to the thickness of ceramic and not sensitive to the charge footprint size on the Ge layer. The other way is experimental image estimation. The final charge footprint size can be estimated according to the position where the light line of resolution board image begins to bend. Both methods show that the charge footprint size is sensitive to the ceramic substrate. The two methods are simple and effective for estimation of charge footprint size of photon counting imaging detector with induction readout. |
文章类型 | Article |
关键词 | Ceramics Germanium Image Resolution Image Sensors Microchannel Plates Photodetectors Photon Counting Ultraviolet Detectors |
WOS标题词 | Science & Technology ; Technology ; Physical Sciences |
DOI | 10.1063/1.3090891 |
收录类别 | SCI ; EI |
关键词[WOS] | RESISTIVE ANODE ; STRIP ANODES ; POSITION ; SYSTEM |
语种 | 英语 |
WOS研究方向 | Instruments & Instrumentation ; Physics |
WOS类目 | Instruments & Instrumentation ; Physics, Applied |
WOS记录号 | WOS:000264776600001 |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | http://ir.opt.ac.cn/handle/181661/25221 |
专题 | 光电子学研究室 |
作者单位 | 1.Chinese Acad Sci, State Key Lab Transient Opt & Photon, Xian Inst Opt & Precis Mech, Xian 710119, Peoples R China 2.Chinese Acad Sci, Grad Univ, Beijing 100039, Peoples R China |
推荐引用方式 GB/T 7714 | Zhang, Xinghua,Zhao, Baosheng,Zhao, Feifei,et al. The estimation of charge footprint size of ultraviolet photon counting imaging detector with induction readout[J]. REVIEW OF SCIENTIFIC INSTRUMENTS,2009,80(3). |
APA | Zhang, Xinghua.,Zhao, Baosheng.,Zhao, Feifei.,Liu, Yong'an.,Miao, Zhenhua.,...&Yan, Qiurong.(2009).The estimation of charge footprint size of ultraviolet photon counting imaging detector with induction readout.REVIEW OF SCIENTIFIC INSTRUMENTS,80(3). |
MLA | Zhang, Xinghua,et al."The estimation of charge footprint size of ultraviolet photon counting imaging detector with induction readout".REVIEW OF SCIENTIFIC INSTRUMENTS 80.3(2009). |
条目包含的文件 | ||||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | ||
The estimation of ch(879KB) | 期刊论文 | 出版稿 | 限制开放 | CC BY-NC-SA | 请求全文 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论