OPT OpenIR  > 光电子学研究室
Progress of NUV and FUV MCP-based photon-counting imaging detectors
LiuYong-An; ZhaoBao-Sheng; WeiYong-Lin; SaiXiao-Feng; YanQiu-Rong; ShengLi-Zhi; Liu Yongan
2011
会议名称International Symposium on Photoelectronic Detection and Imaging 2011: Space Exploration Technologies and Applications
会议录名称Proceedings of SPIE - The International Society for Optical Engineering
页码81961M
会议日期May 24, 2011 - May 26, 2013
会议地点Beijing, China
出版地P.O. Box 10, Bellingham, WA 98227-0032, United States
会议主办者Chinese Society of Astronautics (CAS)
出版者SPIE
产权排序1
摘要In the World Space Observatory-Ultraviolet (WSO-UV) mission, the Long Slit Spectrograph (LSS) instrument will provide low resolution spectra in the range 102-320nm. Both the NUV (160-320nm) and the FUV (102-170nm) channels of LSS use microchannel plates (MCP) working in photon-counting modes as detectors. In this paper, the progress and parameters of NUV and FUV photon-counting imaging detectors were described. For the NUV detector, we developed the detector based on a sealed MCP-image intensifier which comprises input window, photocathode, MCP stack, Ge-layer and its ceramic substrate. To maximize the quantum efficiency, we adopted a Caesium Telluride (Cs2Te) photocathode, which was deposited on input window and mounted close to the MCP. For the FUV detector, because of the lower cut-off wavelength, there are no suitable window materials in this band and the open-faced design should be used to meet the requirements of the detection. Therefore, a Caesium Iodide (CsI) photocathode deposited on the input surface of the MCP was used to optimize detector efficiency. By using an existing wedge and strip anode (WSA), the imaging performance of the NUV and FUV detectors was tested respectively. Experimental results show that the quantum efficiency of Cs2Te is 12.1% (at 230nm), the spatial resolution of NUV and FUV detectors is better than 110μm, the dark count rate of NUV and FUV detectors is about 10.5- and 2.3-counts/s*cm2 respectively.
关键词Detectors Photon-counting Imaging Wso-uv Ultraviolet Mcp
作者部门光电子学研究室
收录类别EI ; CPCI
语种英语
ISSN号0277-786X
文献类型会议论文
条目标识符http://ir.opt.ac.cn/handle/181661/20030
专题光电子学研究室
通讯作者Liu Yongan
推荐引用方式
GB/T 7714
LiuYong-An,ZhaoBao-Sheng,WeiYong-Lin,et al. Progress of NUV and FUV MCP-based photon-counting imaging detectors[C]. P.O. Box 10, Bellingham, WA 98227-0032, United States:SPIE,2011:81961M.
条目包含的文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Progress of NUV and (552KB) 限制开放--请求全文
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[LiuYong-An]的文章
[ZhaoBao-Sheng]的文章
[WeiYong-Lin]的文章
百度学术
百度学术中相似的文章
[LiuYong-An]的文章
[ZhaoBao-Sheng]的文章
[WeiYong-Lin]的文章
必应学术
必应学术中相似的文章
[LiuYong-An]的文章
[ZhaoBao-Sheng]的文章
[WeiYong-Lin]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。