摘要

Coincidence time resolution (CTR) is an important performance parameter of clinical positron emission tomography (PET) detectors, which is dependent on the parameters of the scintillation crystal, the timing measurement methods, and the electronics. In this work, CTRs of PET detectors using dual-ended readout of segmented LYSO arrays were measured with different timing measurement methods. The detector modules were composed of LYSO arrays of 8 x 8 with a crystal size of 3.10 x 3.10 x 20 mm3 or 13 x 13 with a crystals size of 1.88 x 1.88 x 20 mm3 , coupled at each end to an 8 x 8 Hamamatsu SiPM array (S13361-3050NE-08) with pixel active area of 3.00 x 3.00 mm2 and pitch of 3.20 mm. The signals of the SiPM arrays were individually read out and processed by using the TOFPET2 ASICs. The CTRs of the detectors were measured after the timing alignment of the ASICs was performed. Timing measurement methods of the dual-ended readout detector such as the average time of the two SiPMs, the faster time of the two SiPMs, the time of the back SiPM, and the time of the front SiPM were compared. The average time of the two SiPMs provides the best CTR, which is explained by a simple model about the timing measurement methods of a dual-ended readout detector. The detector with one-to-one crystal-to-SiPM coupling provides better CTR than the detector with a crystal size smaller than the pixel size of the SiPM. The best CTR of 367 +/- 6 ps was obtained by using the 8 x 8 LYSO array with unpolished lateral crystal surfaces and ESR reflectors. The CTR of the dual-ended readout detector can be improved if a DOI-dependent timing correction is used.

关键词Data acquisition concepts Data processing methods Gamma camera, SPECT, PET PET/CT, coronary CT angiography (CTA) Gamma detectors (scintillators, CZT, HPGe, HgI etc)
DOI10.1088/1748-0221/18/07/P07003
收录类别SCI
语种英语
WOS记录号WOS:001112020600012
出版者IOP Publishing Ltd
引用统计
文献类型期刊论文
条目标识符http://ir.opt.ac.cn/handle/181661/97227
专题复合材料与器件先进制造研发中心
通讯作者Sun, M. D.
作者单位1.Chinese Acad Sci, Xian Inst Opt & Precis Mech, Xian 710119, Shaanxi, Peoples R China
2.Shenzhen Technol Univ, Ctr Adv Mat Diagnost Technol, Shenzhen 518118, Guangdong, Peoples R China
3.Songshan Lake Mat Lab, Dongguan 523808, Guangdong, Peoples R China
推荐引用方式
GB/T 7714
Sun, M. D.,Zhang, C. H.,Zhao, B. Q.. Coincidence time resolution measurements for dual-ended readout PET detectors[J]. JOURNAL OF INSTRUMENTATION,2023,18(7).
APA Sun, M. D.,Zhang, C. H.,&Zhao, B. Q..(2023).Coincidence time resolution measurements for dual-ended readout PET detectors.JOURNAL OF INSTRUMENTATION,18(7).
MLA Sun, M. D.,et al."Coincidence time resolution measurements for dual-ended readout PET detectors".JOURNAL OF INSTRUMENTATION 18.7(2023).
条目包含的文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Coincidence time res(1951KB)期刊论文出版稿限制开放CC BY-NC-SA请求全文
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Sun, M. D.]的文章
[Zhang, C. H.]的文章
[Zhao, B. Q.]的文章
百度学术
百度学术中相似的文章
[Sun, M. D.]的文章
[Zhang, C. H.]的文章
[Zhao, B. Q.]的文章
必应学术
必应学术中相似的文章
[Sun, M. D.]的文章
[Zhang, C. H.]的文章
[Zhao, B. Q.]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。