摘要

The ferroelectric liquid crystal (FLC)-based wide spectrum polarization imager can quickly acquire the full polarization information of the target, however, the polarization elements error will affect the accuracy of the system polarization parameters (DOP, EOP, and AOP) measurement. In this paper, to investigate the influence of polarization element error on the acquisition of polarization information of the measured target, the influence of element parameter error on the measurement of target polarization parameters is analyzed. First, the working principle of FLC and the structural composition of the system of wide spectrum polarization imager based on FLC are introduced; second, the measurement matrix of the wide spectrum polarization imaging system is calculated based on the CCD spectral response curve, and the variation of the wave plate phase retardation with wavelength; then, the error model of the system for solving the full polarization parameters is established; finally, the effects of the parameter (azimuth angle F1θ, tuned rotation angle F1α, phase retardation F1δ of FLC2; azimuth angle Hθ, phase retardation Hδ of HWP; azimuth angle F2θ, tuned rotation angle F2α, phase retardation F2δ of FLC2; azimuth angle Qθ, phase retardation Qδ of QWP; azimuth angle Pθ of P) errors of each element of the polarization module on the DOP, EOP, and AOP measurements are analyzed. The simulation results show that: with the increase of the error of each element parameter of the polarization module, the measurement error of the polarization parameters are all increasing in different degrees; the error of F2α is the main factor affecting the measurement accuracy of the degree of polarization (DOP), the error of F1α is the main factor affecting the measurement accuracy of the ellipticity of polarization (EOP), and the error of F1θ is the main factor affecting the measurement accuracy of the angle of polarization(AOP); at [-2°,2°], the maximum measurement errors of DOP, EOP, and AOP are 2.83%, 6.98%, and 9.26%, respectively; when the errors of polarization element parameters are certain, the measurement errors will change with different polarization states of the target. The research method and results can provide research ideas and theoretical references for the error analysis research of the wide spectrum polarization imaging system based on FLC or other wide spectrum polarization imaging systems. © 2023 SPIE. All rights reserved.

关键词Full polarization imager Error analysis FLC DOP EOP AOP
作者部门空间光学技术研究室
DOI10.1117/12.3007446
收录类别EI
ISBN号9781510672321
语种英语
ISSN号0277786X;1996756X
EI入藏号20240215330718
引用统计
文献类型会议论文
条目标识符http://ir.opt.ac.cn/handle/181661/97146
专题空间光学技术研究室
通讯作者Chang, Lingying
作者单位1.Schoolof Electronic Engineering, Xi'an University of Posts and Telecommunications, Xi'an; 710121, China;
2.Xi'an Institute of Optics and Precision Mechanics of Cas, Xi'an; 710119, China
推荐引用方式
GB/T 7714
Chang, Lingying,Chen, Kui,Liang, Chi,et al. Error analysis of FLC polarization imager in full polarization state with wide spectrum[C]:SPIE,2023.
条目包含的文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Error analysis of FL(1844KB)会议论文 限制开放CC BY-NC-SA请求全文
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Chang, Lingying]的文章
[Chen, Kui]的文章
[Liang, Chi]的文章
百度学术
百度学术中相似的文章
[Chang, Lingying]的文章
[Chen, Kui]的文章
[Liang, Chi]的文章
必应学术
必应学术中相似的文章
[Chang, Lingying]的文章
[Chen, Kui]的文章
[Liang, Chi]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。