Xi'an Institute of Optics and Precision Mechanics,CAS
Numerical simulation of dual MCP hard x-ray imaging detector on spatial resolution and detection quantum efficiency | |
Liu, Yiheng1,2,3; Li, Lili1,2,3; Chen, Ping1,3; Zhang, Feng4; Gou, Yongsheng1![]() ![]() ![]() | |
2022-11-11 | |
会议名称 | Advanced Fiber Laser Conference (AFL) |
会议录名称 | ADVANCED FIBER LASER CONFERENCE, AFL2022 |
会议日期 | 2022-11-11 |
会议地点 | Changsha, PEOPLES R CHINA |
出版者 | SPIE-INT SOC OPTICAL ENGINEERING |
产权排序 | 1 |
摘要 | Compton radiography is an important diagnostic tool for inertial confinement fusion (ICF), which provides important parameters about integrity, symmetry and.R areal density of the dense cold fuel surrounding the hot spot. The dual MCPs (micro-channel plate) configuration detector as a key component for Compton radiography has the ability to detect hard x-rays at energies from 40 to 200 keV with higher detective quantum efficiency (DQE). In this work, a set of simulation methods for calculating the DQE and spatial resolution of dual MCPs are proposed. The photoelectric conversion and secondary electron multiplication processes of 59 KeV X-rays in double MCPs were simulated. The first piece of MCP with 51% lead content absorb x-rays volumetrically to improve the DQE and the second piece of MCP provides a large gain to multiply the secondary electrons. The simulation results indicate that the spatial resolution of the dual MCP detector is 186 mu m, and the DQE can reach 6.2%, which will ensure the dual MCP-based framing cameras can obtain imploded capsule images with higher signal-to-noise ratio and spatial resolution. The influence of MCP parameters on DQE and spatial resolution was analyzed, and the simulation method will provide an important reference for further optimization of the detector. |
关键词 | micro-channel plate X-ray framing camera Compton radiography detection quantum efficiency spatial resolution |
作者部门 | 条纹相机工程中心 |
DOI | 10.1117/12.2666993 |
收录类别 | CPCI |
ISBN号 | 978-1-5106-6314-5; 978-1-5106-6315-2 |
语种 | 英语 |
ISSN号 | 0277-786X;1996-756X |
WOS记录号 | WOS:001055604400012 |
引用统计 | |
文献类型 | 会议论文 |
条目标识符 | http://ir.opt.ac.cn/handle/181661/96807 |
专题 | 条纹相机工程中心 |
通讯作者 | Chen, Ping; Tian, Jinshou |
作者单位 | 1.Chinese Acad Sci, Xian Inst Opt & Precis Mech, Key Lab Ultra fast photoelectr Diagnost Technol, Xian 710119, Peoples R China 2.Univ Chinese Acad Sci, Beijing 100049, Peoples R China 3.Shanxi Univ, Collaborat Innovat Ctr Extreme Opt, Taiyuan 030006, Peoples R China 4.China Acad Engn Phys, Mianyang 621900, Sichuan, Peoples R China |
推荐引用方式 GB/T 7714 | Liu, Yiheng,Li, Lili,Chen, Ping,et al. Numerical simulation of dual MCP hard x-ray imaging detector on spatial resolution and detection quantum efficiency[C]:SPIE-INT SOC OPTICAL ENGINEERING,2022. |
条目包含的文件 | ||||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | ||
Numerical simulation(1041KB) | 会议论文 | 开放获取 | CC BY-NC-SA | 请求全文 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论