摘要

LED array microscopy is a novel computational imaging technique that can achieve two-dimensional (2D) phase imaging and three-dimensional (3D) refractive index imaging with both high resolution and a large field of view. Although its experimental setup is simple, the errors caused by LED array position and light source central wavelength obviously decrease the quality of reconstructed results. To solve this problem, comprehensive error parameters optimized by the phase smoothing criterion are put forward in this paper. The central wavelength error and 3D misalignment model with six freedom degree errors of LED array are considered as the comprehensive error parameters when the spatial positional and optical features of arbitrarily placed LED array are unknown. Phase smoothing criterion is also introduced to the cost function for optimizing comprehensive error parameters to improve the convergence results. Compared with current system correction methods, the simulation and experimental results show that the proposed method in this paper has the best reconstruction accuracy, which can be well applied to an LED array microscope system with unknown positional and optical features of the LED array. © 2023 Optica Publishing Group under the terms of the Optica Open Access Publishing Agreement.

DOI10.1364/BOE.497681
收录类别SCI ; EI
语种英语
WOS记录号WOS:001072232500001
出版者Optica Publishing Group (formerly OSA)
EI入藏号20233914773799
引用统计
文献类型期刊论文
条目标识符http://ir.opt.ac.cn/handle/181661/96797
专题先进光学仪器研究室
通讯作者Zhang, Lu
作者单位1.State Key Laboratory for Manufacturing System Engineering, School of Mechanical Engineering, Xi’an Jiaotong University, Xi’an; 710049, China;
2.Xi’an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi’an; 710119, China;
3.Mengchao Hepatobiliary Hospital of Fujian Medical University, The United Innovation of Mengchao Hepatobiliary Technology Key Laboratory of Fujian Province, Fuzhou; 350025, China;
4.Key Laboratory of Biomedical Information Engineering of Ministry of Education, Xi’an Jiaotong University, Xi’an; 710049, China
推荐引用方式
GB/T 7714
Yang, Zewen,Zhang, Lu,Liu, Tong,et al. LED array microscopy system correction method with comprehensive error parameters optimized by phase smoothing criterion[J]. Biomedical Optics Express,2023,14(9):4696-4712.
APA Yang, Zewen.,Zhang, Lu.,Liu, Tong.,Wu, Haoyu.,Tang, Zhiyuan.,...&Zhao, Hong.(2023).LED array microscopy system correction method with comprehensive error parameters optimized by phase smoothing criterion.Biomedical Optics Express,14(9),4696-4712.
MLA Yang, Zewen,et al."LED array microscopy system correction method with comprehensive error parameters optimized by phase smoothing criterion".Biomedical Optics Express 14.9(2023):4696-4712.
条目包含的文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
LED array microscopy(58691KB)期刊论文出版稿限制开放CC BY-NC-SA请求全文
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Yang, Zewen]的文章
[Zhang, Lu]的文章
[Liu, Tong]的文章
百度学术
百度学术中相似的文章
[Yang, Zewen]的文章
[Zhang, Lu]的文章
[Liu, Tong]的文章
必应学术
必应学术中相似的文章
[Yang, Zewen]的文章
[Zhang, Lu]的文章
[Liu, Tong]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。