Optimizing the accuracy of microcomb-based microwave photonic transversal signal processors | |
Sun, Yang1; Wu, Jiayang1; Li, Yang1; Xu, Xingyuan2; Ren, Guanghui3; Tan, Mengxi3; Chu, Sai Tak4; Little, Brent E.5; Morandotti, Roberto6; Mitchell, Arnan3; Moss, David J.1 | |
作者部门 | 瞬态光学研究室 |
发表期刊 | Journal of Lightwave Technology
![]() |
ISSN | 07338724;15582213 |
页码 | 1-15 |
产权排序 | 5 |
摘要 | Microwave photonic (MWP) transversal signal processors offer a compelling solution for realizing versatile high-speed information processing by combining the advantages of reconfigurable electrical digital signal processing and high-bandwidth photonic processing. With the capability of generating a number of discrete wavelengths from micro-scale resonators, optical microcombs are powerful multi-wavelength sources for implementing MWP transversal signal processors with significantly reduced size, power consumption, and complexity. By using microcomb-based MWP transversal signal processors, a diverse range of signal processing functions have been demonstrated recently. In this paper, we provide a detailed analysis for the processing inaccuracy that is induced by the imperfect response of experimental components. First, we investigate the errors arising from different sources including imperfections in the microcombs, the chirp of electro-optic modulators, chromatic dispersion of the dispersive module, shaping errors of the optical spectral shapers, and noise of the photodetector. Next, we provide a global picture quantifying the impact of different error sources on the overall system performance. Finally, we introduce feedback control to compensate the errors caused by experimental imperfections and achieve significantly improved accuracy. These results provide a guide for optimizing the accuracy of microcomb-based MWP transversal signal processors. IEEE |
关键词 | Microwave photonics optical microcombs optical signal processing |
DOI | 10.1109/JLT.2023.3314526 |
收录类别 | SCI ; EI |
语种 | 英语 |
WOS记录号 | WOS:001122526000027 |
出版者 | Institute of Electrical and Electronics Engineers Inc. |
EI入藏号 | 20233814765871 |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | http://ir.opt.ac.cn/handle/181661/96795 |
专题 | 瞬态光学研究室 |
作者单位 | 1.Optical Sciences Center, Swinburne University of Technology, Hawthorn, Australia; 2.State Key Laboratory of Information Photonics and Optical Communications, Beijing University of Posts and Telecommunications, Beijing, China; 3.Integrated Photonics and Applications Centre, School of Engineering, RMIT University, Melbourne, Australia; 4.Department of Physics, City University of Hong Kong, Hong Kong; 5.State Key Laboratory of Transient Optics and Photonics, Xian Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xian, China; 6.INRS nergie, Matriaux et Tlcommunications, Varennes, Canada |
推荐引用方式 GB/T 7714 | Sun, Yang,Wu, Jiayang,Li, Yang,et al. Optimizing the accuracy of microcomb-based microwave photonic transversal signal processors[J]. Journal of Lightwave Technology:1-15. |
APA | Sun, Yang.,Wu, Jiayang.,Li, Yang.,Xu, Xingyuan.,Ren, Guanghui.,...&Moss, David J.. |
MLA | Sun, Yang,et al."Optimizing the accuracy of microcomb-based microwave photonic transversal signal processors".Journal of Lightwave Technology |
条目包含的文件 | ||||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | ||
Optimizing the accur(2746KB) | 期刊论文 | 出版稿 | 限制开放 | CC BY-NC-SA | 请求全文 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论