High-accuracy twist measurement based on the spherical wave Talbot effect for a bi-grid modulation collimator | |
Liu, Shengrun1,2![]() ![]() ![]() | |
作者部门 | 月球与深空探测技术研究室 |
2021-08-01 | |
发表期刊 | Applied Optics
![]() |
ISSN | 1559128X;21553165 |
卷号 | 60期号:22页码:6547-6553 |
产权排序 | 1 |
摘要 | The bi-grid modulation collimator is a significant way for imaging solar flares in hard x rays. It implements many subcollimators that consist of separated grid pairs (so-called front grid and rear grid) whose line orientations are parallel. However, when the twist of the front grid with respect to the other will be induced during testing of the bi-grid modulation collimator in the ground verification phase, the line orientation of the grid pairs are no longer parallel. Knowledge of the relative twist between the rear grid and the front grid is very helpful in improving the imaging quality of the bi-grid collimator. However, because of the wide spacing between grid pairs and the requirement of high measurement accuracy, it is a challenge to measure the relative twist. To meet this demand, a method based on the spherical wave Talbot effect is proposed. The Talbot images of the front grid and the rear grid are imaged on the same plane, respectively, through two proper spherical waves. The relative twist can be figured out through the angle between the stripes in the Talbot images of the front grid and the rear grid. In experiments, the measurement accuracy of the relative twist angle can reach 9 arcsec in the range of 370 arcsec. It demonstrates that this method can effectively measure the relative twist between the grid pairs with very high accuracy. © 2021 Optical Society of America |
DOI | 10.1364/AO.429980 |
收录类别 | SCI ; EI |
语种 | 英语 |
WOS记录号 | WOS:000680164700039 |
出版者 | The Optical Society |
EI入藏号 | 20213110716058 |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | http://ir.opt.ac.cn/handle/181661/94996 |
专题 | 月球与深空探测技术研究室 |
通讯作者 | Liu, Shengrun |
作者单位 | 1.Xi’an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xinxi Road, Xi’an; 710119, China; 2.University of Chinese Academy of Sciences, Yuquan Road, Beijing; 100049, China |
推荐引用方式 GB/T 7714 | Liu, Shengrun,Xue, Bin,Cheng, Ying,et al. High-accuracy twist measurement based on the spherical wave Talbot effect for a bi-grid modulation collimator[J]. Applied Optics,2021,60(22):6547-6553. |
APA | Liu, Shengrun,Xue, Bin,Cheng, Ying,&Yang, Jianfeng.(2021).High-accuracy twist measurement based on the spherical wave Talbot effect for a bi-grid modulation collimator.Applied Optics,60(22),6547-6553. |
MLA | Liu, Shengrun,et al."High-accuracy twist measurement based on the spherical wave Talbot effect for a bi-grid modulation collimator".Applied Optics 60.22(2021):6547-6553. |
条目包含的文件 | ||||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | ||
High-accuracy twist (6846KB) | 期刊论文 | 出版稿 | 限制开放 | CC BY-NC-SA | 请求全文 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论