Non-contact heart rate and respiratory monitoring based on Imaging Photoplethysmography at fingertip | |
Qiao WenLong1,2; Zhou Liang2![]() ![]() | |
2020 | |
会议名称 | Applied Optics and Photonics China (AOPC) Conference - Optical Spectroscopy and Imaging and Biomedical Optics |
会议录名称 | AOPC 2020: OPTICAL SPECTROSCOPY AND IMAGING; AND BIOMEDICAL OPTICS |
卷号 | 11566 |
会议日期 | 2020-11-30 |
会议地点 | Beijing, PEOPLES R CHINA |
出版者 | SPIE-INT SOC OPTICAL ENGINEERING |
产权排序 | 1 |
摘要 | In this paper, we use imaging photoplethysmography (IPPG) to realize non-contact measurement of blood volume change of human fingertip, which can avoid distortion of blood vessel wall caused by pressure applied to fingertip. We use CMOS color camera to collect signals and white LED as light source. In the process of signal processing, we abandon the traditional morphological filtering algorithm in the form of double-layer cascade, and use single-layer morphological filtering algorithm. Experiments show that the single-layer morphological filtering algorithm has a good effect of eliminating baseline drift of signals, and can perfectly retain the detail components of signals without shifting the transverse components. We proposed a peak-to-valley value detection algorithm to calculate the heart rate by detecting the time interval between the adjacent peaks value. The experiment compared the accuracy of calculating the heart rate by using the traditional fast Fourier transform and the heart rate based on peak-to-valley value detection. The respiration rate was detected by using the third-order Butterworth filter. The accuracy of heart rate monitoring can be achieved at 97.86% and the accuracy of respiration monitoring can be achieved at 95.02%. |
关键词 | Non-contact blood volume heart rate respiration rate imaging photoplethysmography (IPPG) |
作者部门 | 光电跟踪与测量技术研究室 |
DOI | 10.1117/12.2579405 |
收录类别 | CPCI |
ISBN号 | 978-1-5106-3954-6 |
语种 | 英语 |
ISSN号 | 0277-786X;1996-756X |
WOS记录号 | WOS:000661249000034 |
引用统计 | |
文献类型 | 会议论文 |
条目标识符 | http://ir.opt.ac.cn/handle/181661/94942 |
专题 | 光电跟踪与测量技术研究室 |
通讯作者 | Zhou Liang |
作者单位 | 1.Chinese Academy of Sciences Xi'an Institute of Optics & Precision Mechanics, CAS 2.Chinese Academy of Sciences University of Chinese Academy of Sciences, CAS |
推荐引用方式 GB/T 7714 | Qiao WenLong,Zhou Liang,Liu Zhaohui,et al. Non-contact heart rate and respiratory monitoring based on Imaging Photoplethysmography at fingertip[C]:SPIE-INT SOC OPTICAL ENGINEERING,2020. |
条目包含的文件 | ||||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | ||
Non-contact heart ra(499KB) | 会议论文 | 限制开放 | CC BY-NC-SA | 请求全文 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论