OPT OpenIR  > 光谱成像技术研究室
Optimal optical path difference of an asymmetric common-path coherent-dispersion spectrometer
Chen, Shasha1,2,3; Wei, Ruyi1,3,4; Xie, Zhengmao3; Wu, Yinhua5; Di, Lamei1,3; Wang, Feicheng1,3; Zhai, Yang6,7
作者部门光谱成像技术研究室
2021-06-01
发表期刊Applied Optics
ISSN1559128X; 21553165
卷号60期号:16页码:4535-4543
产权排序1
摘要

Optical path difference (OPD) is a very significant parameter in the asymmetric common-path coherent-dispersion spectrometer (CODES), which directly determines the performance of the CODES. In order to improve the performance of the instrument as much as possible, a temperature-compensated optimal optical path difference (TOOPD) method is proposed. The method does not only consider the influence of temperature change on the OPD but also effectively solves the problem that the optimal OPD cannot be obtained simultaneously at different wavelengths. Taking the spectral line with a Gaussian-type power spectral density distribution as a representative, the relational expression between the OPD and the visibility of interference fringes formed by the CODES is derived for the stellar absorption/emission line. Further, the optimal OPD is deduced according to the efficiency function, and the relationship between the optimalOPDand wavelength is analyzed. Then, based on the materials' dispersion characteristics, different optical materials are combined and added to the interferometer's reflected and transmitted optical path to implement the optimalOPDat different wavelengths, thereby improving the detection precision. Meanwhile, the materials whose refractive index negatively changes with temperature are selected to reduce or even offset the temperature impact on OPD, and hence the system's stability is improved and further improves the detection precision. Under certain input conditions, the material combination that approximates the optimal OPD is performed within the range of 0.66-0.9 μm. The simulation results show that the maximal difference between the optimal OPD obtained by the efficiency function and the OPD produced by the material combination is 0.733 mm for the absorption line and 1.122 mm for the emission line, which is reduced by 1 time compared with only one material. The influence of temperature on the OPD can be reduced by 2-3 orders of magnitude by material combination, which greatly ameliorates the stability of the whole spectrometer. Hence, the TOOPD method provides a new idea for further improving the high-precision radial velocity detection of the asymmetric common-pathCODES. ©2021 Optical Society of America.

DOI10.1364/AO.425491
收录类别SCI ; EI
语种英语
WOS记录号WOS:000654242400023
出版者The Optical Society
EI入藏号20212210426952
引用统计
被引频次:3[WOS]   [WOS记录]     [WOS相关记录]
文献类型期刊论文
条目标识符http://ir.opt.ac.cn/handle/181661/94824
专题光谱成像技术研究室
通讯作者Wei, Ruyi
作者单位1.CAS Key Laboratory of Spectral Imaging Technology, Xi'an; 710119, China;
2.School of Optoelectronics, University of Chinese Academy of Sciences, Beijing; 100049, China;
3.Xi'an Institute of Optics Precision and Mechanic of Chinese Academy of Sciences, Xi'an; 710119, China;
4.Electronic Information School, Wuhan University, Wuhan; 430072, China;
5.School of Optoelectronics Engineering, Xi'an Technological University, Xi'an; 710021, China;
6.National Astronomical Observatories/Nanjing Institute of Astronomical Optics & Technology, Chinese Academy of Sciences, Nanjing; 210042, China;
7.Key Laboratory of Astronomical Optics and Technology, Nanjing Institute of Astronomical Optics and Technology, Chinese Academy of Sciences, Nanjing; 210042, China
推荐引用方式
GB/T 7714
Chen, Shasha,Wei, Ruyi,Xie, Zhengmao,et al. Optimal optical path difference of an asymmetric common-path coherent-dispersion spectrometer[J]. Applied Optics,2021,60(16):4535-4543.
APA Chen, Shasha.,Wei, Ruyi.,Xie, Zhengmao.,Wu, Yinhua.,Di, Lamei.,...&Zhai, Yang.(2021).Optimal optical path difference of an asymmetric common-path coherent-dispersion spectrometer.Applied Optics,60(16),4535-4543.
MLA Chen, Shasha,et al."Optimal optical path difference of an asymmetric common-path coherent-dispersion spectrometer".Applied Optics 60.16(2021):4535-4543.
条目包含的文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Optimal optical path(6969KB)期刊论文出版稿限制开放CC BY-NC-SA请求全文
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Chen, Shasha]的文章
[Wei, Ruyi]的文章
[Xie, Zhengmao]的文章
百度学术
百度学术中相似的文章
[Chen, Shasha]的文章
[Wei, Ruyi]的文章
[Xie, Zhengmao]的文章
必应学术
必应学术中相似的文章
[Chen, Shasha]的文章
[Wei, Ruyi]的文章
[Xie, Zhengmao]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。