Using CNN and HHT to Predict Blood Pressure Level Based on Photoplethysmography and Its Derivatives | |
Sun, Xiaoxiao1,2; Zhou, Liang1![]() ![]() | |
作者部门 | 光电跟踪与测量技术研究室 |
2021-04 | |
发表期刊 | BIOSENSORS-BASEL
![]() |
ISSN | 2079-6374 |
卷号 | 11期号:4 |
产权排序 | 1 |
摘要 | According to the WTO, there were 1.13 billion hypertension patients worldwide in 2015. The WTO encouraged people to check the blood pressure regularly because a large amount of patients do not have any symptoms. However, traditional cuff measurement results are not enough to represent the patient ' s blood pressure status over a period of time. Therefore, there is an urgent need for portable, easy to operate, continuous measurement, and low-cost blood pressure measuring devices. In this paper, we adopted the convolutional neural network (CNN), based on the Hilbert-Huang Transform (HHT) method, to predict blood pressure (BP) risk level using photoplethysmography (PPG). Considering that the PPG ' s first and second derivative signals are related to atherosclerosis and vascular elasticity, we created a dataset called PPG+; the images of PPG+ carry information on PPG and its derivatives. We built three classification experiments by collecting 582 data records (the length of each record is 10 s) from the Medical Information Mart for Intensive Care (MIMIC) database: NT (normotension) vs. HT (hypertension), NT vs. PHT (prehypertension), and (NT + PHT) vs. HT; the F1 scores of the PPG + experiments using AlexNet were 98.90%, 85.80%, and 93.54%, respectively. We found that, first, the dataset established by the HHT method performed well in the BP grade prediction experiment. Second, because the Hilbert spectra of the PPG are simple and periodic, AlexNet, which has only 8 layers, got better results. More layers instead increased the cost and difficulty of training. |
关键词 | blood pressure photoplethysmography derivatives of PPG convolutional neural network ensemble empirical mode decomposition |
DOI | 10.3390/bios11040120 |
收录类别 | SCI |
语种 | 英语 |
WOS记录号 | WOS:000642783800001 |
出版者 | MDPI |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | http://ir.opt.ac.cn/handle/181661/94725 |
专题 | 光电跟踪与测量技术研究室 |
通讯作者 | Zhou, Liang |
作者单位 | 1.Xian Inst Opt & Precis Mech CAS, Xian 710119, Peoples R China 2.Univ Chinese Acad Sci, Beijing 100049, Peoples R China 3.Univ Queensland, EAIT Engn Architecture & Informat Technol Dept, Brisbane, Qld 4072, Australia |
推荐引用方式 GB/T 7714 | Sun, Xiaoxiao,Zhou, Liang,Chang, Shendong,et al. Using CNN and HHT to Predict Blood Pressure Level Based on Photoplethysmography and Its Derivatives[J]. BIOSENSORS-BASEL,2021,11(4). |
APA | Sun, Xiaoxiao,Zhou, Liang,Chang, Shendong,&Liu, Zhaohui.(2021).Using CNN and HHT to Predict Blood Pressure Level Based on Photoplethysmography and Its Derivatives.BIOSENSORS-BASEL,11(4). |
MLA | Sun, Xiaoxiao,et al."Using CNN and HHT to Predict Blood Pressure Level Based on Photoplethysmography and Its Derivatives".BIOSENSORS-BASEL 11.4(2021). |
条目包含的文件 | ||||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | ||
Using CNN and HHT to(2639KB) | 期刊论文 | 出版稿 | 限制开放 | CC BY-NC-SA | 请求全文 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论