OPT OpenIR  > 信息光子学研究室
Fluorescence Hydrogen Peroxide Probe Based on a Microstructured Polymer Optical Fiber Modified with a Titanium Dioxide Film
Li, Dongdong1,2; Wang, Lili1; Lili Wang
2010-05-01
发表期刊APPLIED SPECTROSCOPY
ISSN0003-7028
卷号64期号:5页码:514-519
摘要A highly sensitive microstructured polymer optical fiber (MPOF) probe for hydrogen peroxide was made by forming a rhodamine 6G-doped titanium dioxide film on the side walls of array holes in an MPOF. It was found that hydrogen peroxide only has a response to the MPOF probe in a certain concentration of potassium iodide in sulfuric acid solution. The calibration graph of fluorescence intensity versus hydrogen peroxide concentration is linear in the range of 1.6 x 10(-7) mol/L to 9.6 x 10(-5) mol/L. The method, with high sensitivity and a wide linear range, has been applied to the determination of trace amounts of hydrogen peroxide in a few real samples, such as rain water and contact lens disinfectant, with satisfactory results.
文章类型Article
关键词Hydrogen Peroxide Fluorescence Probe Microstructured Polymer Optical Fiber Titanium Oxide Film
学科领域信息光学
WOS标题词Science & Technology ; Technology
收录类别SCI ; EI
关键词[WOS]PHOTONIC CRYSTAL FIBERS ; THIN-FILMS ; HORSERADISH-PEROXIDASE ; SENSORS ; FABRICATION ; BIOSENSOR ; OXIDASE ; WATER
语种英语
WOS研究方向Instruments & Instrumentation ; Spectroscopy
WOS类目Instruments & Instrumentation ; Spectroscopy
WOS记录号WOS:000277846600008
引用统计
被引频次:18[WOS]   [WOS记录]     [WOS相关记录]
文献类型期刊论文
条目标识符http://ir.opt.ac.cn/handle/181661/8420
专题信息光子学研究室
通讯作者Lili Wang
作者单位1.Chinese Acad Sci, State Key Lab Transient Opt & Photon, Xian Inst Opt & Precis Mech, Xian 710119, Shaanxi, Peoples R China
2.Chinese Acad Sci, Grad Univ, Beijing 100039, Peoples R China
推荐引用方式
GB/T 7714
Li, Dongdong,Wang, Lili,Lili Wang. Fluorescence Hydrogen Peroxide Probe Based on a Microstructured Polymer Optical Fiber Modified with a Titanium Dioxide Film[J]. APPLIED SPECTROSCOPY,2010,64(5):514-519.
APA Li, Dongdong,Wang, Lili,&Lili Wang.(2010).Fluorescence Hydrogen Peroxide Probe Based on a Microstructured Polymer Optical Fiber Modified with a Titanium Dioxide Film.APPLIED SPECTROSCOPY,64(5),514-519.
MLA Li, Dongdong,et al."Fluorescence Hydrogen Peroxide Probe Based on a Microstructured Polymer Optical Fiber Modified with a Titanium Dioxide Film".APPLIED SPECTROSCOPY 64.5(2010):514-519.
条目包含的文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Fluorescence Hydroge(4028KB)期刊论文出版稿限制开放CC BY-NC-SA请求全文
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Li, Dongdong]的文章
[Wang, Lili]的文章
[Lili Wang]的文章
百度学术
百度学术中相似的文章
[Li, Dongdong]的文章
[Wang, Lili]的文章
[Lili Wang]的文章
必应学术
必应学术中相似的文章
[Li, Dongdong]的文章
[Wang, Lili]的文章
[Lili Wang]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。