Angular micro-vibration test of an agile satellite high resolution camera based on liner accelerometer | |
Cui, Kai; Zheng, Zhiqi; Gao, Xiong; Yang, Yongqing; Li, Zhiguo; Li, Shuxiu | |
2019 | |
会议名称 | 3rd International Conference on Photonics and Optical Engineering |
会议录名称 | Third International Conference on Photonics and Optical Engineering |
卷号 | 11052 |
会议日期 | 2018-12-05 |
会议地点 | Xi'an, China |
出版者 | SPIE |
产权排序 | 1 |
摘要 | The angular micro-vibration of a high resolution camera mounting on an agile satellite was achieved based on pairs of liner accelerometers alignment and numerical integration method. Three pairs of sensors were mounted at different portion of the satellite for studying the structure transfer character, including the Reaction Wheel (RW)interface, the camera interface and the camera tail. The results showed that the RW original micro-vibration standard deviation (STD) output acquired at the RW interference was 1.63μrad at RW 400rpm and increased to 2.43μrad when the RW speed up to 800rpm. When transferring from RW to the camera interface, the angular vibration response STD was attenuated to 0.31μrad@400rpm and 0.27μrad@800rpm, and finally to the camera tail the angular vibration response STD became 0.31μrad@400rpm and 0.30μrad@800rpm. We can see that the satellite-camera structure has a good attenuation effect on the micro-vibration, the output angular micro-vibration STD is about 0.31μrad with an input of 1.63μrad?2.43μrad. the stiffness of the camera is pretty good, ensuring that the micro-vibration STD difference between the camera flange and the camera tail is smaller 0.03μrad. In addition, we found that the FOGs useful bandwidth wasn't insufficient when acquiring about 340Hz main frequency vibration signal in our case, even though a higher stiffness flange was recommended which connecting the FOG and camera. ? 2019 SPIE. |
作者部门 | 光电跟踪与测量技术研究室 |
DOI | 10.1117/12.2521437 |
收录类别 | EI ; CPCI |
ISBN号 | 9781510627796 |
语种 | 英语 |
ISSN号 | 0277786X;1996765X |
WOS记录号 | WOS:000464740100016 |
EI入藏号 | 20190806535037 |
引用统计 | |
文献类型 | 会议论文 |
条目标识符 | http://ir.opt.ac.cn/handle/181661/31281 |
专题 | 光电跟踪与测量技术研究室 |
作者单位 | Xi'An Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi'an, Shaanxi; 710119, China |
推荐引用方式 GB/T 7714 | Cui, Kai,Zheng, Zhiqi,Gao, Xiong,et al. Angular micro-vibration test of an agile satellite high resolution camera based on liner accelerometer[C]:SPIE,2019. |
条目包含的文件 | ||||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | ||
Angular micro-vibrat(626KB) | 会议论文 | 限制开放 | CC BY-NC-SA | 请求全文 |