Stokes polarimeter for the measurement of full linearly Stokes parameters with immunity to Gaussian and Poisson noise | |
Li, Siyuan1,2,3,4; Quan, Naicheng5; Zhang, Chunmin6; Mu, Tingkui6; Hu, Bingliang1![]() | |
作者部门 | 光谱成像技术实验室 |
2018-12 | |
发表期刊 | Optik
![]() |
ISSN | 00304026 |
卷号 | 175页码:8-16 |
产权排序 | 1 |
摘要 | The optimization of Stokes polarimeter to determine the full linearly Stokes parameters in the presence of additive Gaussian noise and signal-dependent Poisson shot noise is addressed. The measurement matrix to minimize the total measurement variance on the full linearly Stokes parameters is optimized. Compared with the previous measurement matrix, the optimal measurement matrix proposed in this paper can effectively improve the measurement precision of the full linearly Stokes parameters statistically. In addition, a practical configuration of Stokes polarimeter is optimized by a cost function to generate the optimal measurement matrix. For the Stokes polarimeter composed by a variable retarder and fixed polarizer, the optimal measurement matrix can be easily generated by a 179.28° retardation with a pair of azimuths ±78.84° and a 179.64° retardation with a pair of azimuths ±33.84°. ? 2018 Elsevier GmbH |
关键词 | Polarimetry Stokes Parameters Polarization State |
DOI | 10.1016/j.ijleo.2018.08.054 |
收录类别 | SCI ; EI |
语种 | 英语 |
WOS记录号 | WOS:000449312200002 |
出版者 | Elsevier GmbH |
EI入藏号 | 20183705799679 |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | http://ir.opt.ac.cn/handle/181661/30629 |
专题 | 光谱成像技术研究室 |
通讯作者 | Quan, Naicheng |
作者单位 | 1.Xi'an Institute of Optics and Precision Mechanics of CAS, China; 2.Xi'an Jiaotong University, China; 3.University of Chinese Academy of Sciences, China; 4.The Key Laboratory Spectral Imaging Technology, Chinese Academy, China; 5.School of Materials Science and Engineering, Xi'an University of Technology, China; 6.Institute of Space Optics, Xi'an Jiaotong University, China |
推荐引用方式 GB/T 7714 | Li, Siyuan,Quan, Naicheng,Zhang, Chunmin,et al. Stokes polarimeter for the measurement of full linearly Stokes parameters with immunity to Gaussian and Poisson noise[J]. Optik,2018,175:8-16. |
APA | Li, Siyuan,Quan, Naicheng,Zhang, Chunmin,Mu, Tingkui,&Hu, Bingliang.(2018).Stokes polarimeter for the measurement of full linearly Stokes parameters with immunity to Gaussian and Poisson noise.Optik,175,8-16. |
MLA | Li, Siyuan,et al."Stokes polarimeter for the measurement of full linearly Stokes parameters with immunity to Gaussian and Poisson noise".Optik 175(2018):8-16. |
条目包含的文件 | ||||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | ||
Stokes polarimeter f(1361KB) | 期刊论文 | 出版稿 | 限制开放 | CC BY-NC-SA | 请求全文 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论