OPT OpenIR  > 瞬态光学研究室
System calibration method for Fourier ptychographic microscopy
Pan, An1,2; Zhang, Yan1,2; Zhao, Tianyu1,2; Wang, Zhaojun1,2; Dan, Dan1,2; Lei, Ming1; Yao, Baoli1
作者部门瞬态光学技术国家重点实验室
2017-09-01
发表期刊JOURNAL OF BIOMEDICAL OPTICS
ISSN1083-3668
卷号22期号:9
产权排序1
摘要

Fourier ptychographic microscopy (FPM) is a recently proposed computational imaging technique with both high-resolution and wide field of view. In current FPM imaging platforms, systematic error sources come from aberrations, light-emitting diode (LED) intensity fluctuation, parameter imperfections, and noise, all of which may severely corrupt the reconstruction results with similar artifacts. Therefore, it would be unlikely to distinguish the dominating error from these degraded reconstructions without any preknowledge. In addition, systematic error is generally a mixture of various error sources in the real situation, and it cannot be separated due to their mutual restriction and conversion. To this end, we report a system calibration procedure, termed SC-FPM, to calibrate the mixed systematic errors simultaneously from an overall perspective, based on the simulated annealing algorithm, the LED intensity correction method, the nonlinear regression process, and the adaptive step-size strategy, which involves the evaluation of an error metric at each iteration step, followed by the re-estimation of accurate parameters. The performance achieved both in simulations and experiments demonstrates that the proposed method outperforms other state-of-the-art algorithms. The reported system calibration scheme improves the robustness of FPM, relaxes the experiment conditions, and does not require any preknowledge, which makes the FPM more pragmatic. (C) 2017 Society of Photo-Optical Instrumentation Engineers (SPIE)

文章类型Article
关键词Computational Imaging Phase Retrieval Fourier Ptychography
WOS标题词Science & Technology ; Life Sciences & Biomedicine ; Physical Sciences
DOI10.1117/1.JBO.22.9.096005
收录类别SCI ; EI
关键词[WOS]LED ARRAY MICROSCOPE ; ILLUMINATION ; FIELD
语种英语
WOS研究方向Biochemistry & Molecular Biology ; Optics ; Radiology, Nuclear Medicine & Medical Imaging
项目资助者National Natural Science Foundation of China (NSFC)(61377008 ; 81427802)
WOS类目Biochemical Research Methods ; Optics ; Radiology, Nuclear Medicine & Medical Imaging
WOS记录号WOS:000413570000029
引用统计
被引频次:77[WOS]   [WOS记录]     [WOS相关记录]
文献类型期刊论文
条目标识符http://ir.opt.ac.cn/handle/181661/29392
专题瞬态光学研究室
作者单位1.Chinese Acad Sci, Xian Inst Opt & Precis Mech, State Key Lab Transient Opt & Photon, Xian, Shaanxi, Peoples R China
2.Univ Chinese Acad Sci, Beijing, Peoples R China
推荐引用方式
GB/T 7714
Pan, An,Zhang, Yan,Zhao, Tianyu,et al. System calibration method for Fourier ptychographic microscopy[J]. JOURNAL OF BIOMEDICAL OPTICS,2017,22(9).
APA Pan, An.,Zhang, Yan.,Zhao, Tianyu.,Wang, Zhaojun.,Dan, Dan.,...&Yao, Baoli.(2017).System calibration method for Fourier ptychographic microscopy.JOURNAL OF BIOMEDICAL OPTICS,22(9).
MLA Pan, An,et al."System calibration method for Fourier ptychographic microscopy".JOURNAL OF BIOMEDICAL OPTICS 22.9(2017).
条目包含的文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
System calibration m(5142KB)期刊论文出版稿限制开放CC BY-NC-SA请求全文
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Pan, An]的文章
[Zhang, Yan]的文章
[Zhao, Tianyu]的文章
百度学术
百度学术中相似的文章
[Pan, An]的文章
[Zhang, Yan]的文章
[Zhao, Tianyu]的文章
必应学术
必应学术中相似的文章
[Pan, An]的文章
[Zhang, Yan]的文章
[Zhao, Tianyu]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。