Radiometric calibration of photographic camera with a composite plane array CCD in laboratory
其他题名复合面阵CCD摄影相机的实验室辐射定标
Li, Jing; Zhao, Jian-Ke; Chang, Ming; Hu, Xin-Rong; Li, Jing (lijing@opt.ac.cn)
作者部门检测技术研究中心
2017
发表期刊Guangxue Jingmi Gongcheng/Optics and Precision Engineering
ISSN1004924X
卷号25期号:1页码:73-83
产权排序1
摘要

To eliminate the serious vignetting phenomenon and to solve the difficulty of choosing a relatively positioning target value problems among CCDs during the radiometric calibration of the whole image plane of the photographic camera with a composite plane array CCD, a method for radiometric calibration of multi-CCDs was proposed. After the dark signal calibration on each pixel, the gray value of the pixel in the vignetting area was revised, and by choosing the appropriate relative calibration target gray value of the whole image plane, the radiometric calibration of the photographic camera with a composite plane array CCD was eventually completed. Through analysis of the gray distribution characteristics of vignetting area, the gray correction method for all kinds of explosion time and radiance was proposed. With calculation of fitting coefficient between each CCD gray value and the input radiance respectively, the coefficient with global minimum fitting error was chosen to calculate the relative calibration target gray value corresponding to radiance. After the radiometric calibration using this method, the non-uniformity of the whole image plane of the photographic camera with a composite plane array CCD is reduced from above 20% to better than 2%, and the accuracy of the absolute calibration is 4.23%. The result indicates that the proposed calibration method is appropriate for the calibration of composite planes array CCD. The accuracy of the calibration satisfies the radiometric calibration requirement of aerial cameras. © 2017, Science Press. All right reserved.

DOI10.3788/OPE.20172501.0073
收录类别EI ; CSCD
语种中文
引用统计
文献类型期刊论文
条目标识符http://ir.opt.ac.cn/handle/181661/28928
专题检测技术研究中心
通讯作者Li, Jing (lijing@opt.ac.cn)
作者单位Xi'an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi'an; 710119, China
推荐引用方式
GB/T 7714
Li, Jing,Zhao, Jian-Ke,Chang, Ming,et al. Radiometric calibration of photographic camera with a composite plane array CCD in laboratory[J]. Guangxue Jingmi Gongcheng/Optics and Precision Engineering,2017,25(1):73-83.
APA Li, Jing,Zhao, Jian-Ke,Chang, Ming,Hu, Xin-Rong,&Li, Jing .(2017).Radiometric calibration of photographic camera with a composite plane array CCD in laboratory.Guangxue Jingmi Gongcheng/Optics and Precision Engineering,25(1),73-83.
MLA Li, Jing,et al."Radiometric calibration of photographic camera with a composite plane array CCD in laboratory".Guangxue Jingmi Gongcheng/Optics and Precision Engineering 25.1(2017):73-83.
条目包含的文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
复合面阵CCD摄影相机的实验室辐射定标_(855KB)期刊论文作者接受稿限制开放CC BY-NC-SA请求全文
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Li, Jing]的文章
[Zhao, Jian-Ke]的文章
[Chang, Ming]的文章
百度学术
百度学术中相似的文章
[Li, Jing]的文章
[Zhao, Jian-Ke]的文章
[Chang, Ming]的文章
必应学术
必应学术中相似的文章
[Li, Jing]的文章
[Zhao, Jian-Ke]的文章
[Chang, Ming]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。