Stray Light Measurement for Point Source Transmittance of Space Optical Systems | |
Chen, Qinfang1; Ma, Zhen1![]() ![]() | |
2016 | |
会议名称 | 8th International Symposium on Advanced Optical Manufacturing and Testing Technology (AOMATT) - Optical Test, Measurement Technology, and Equipment |
会议录名称 | 8TH INTERNATIONAL SYMPOSIUM ON ADVANCED OPTICAL MANUFACTURING AND TESTING TECHNOLOGY: OPTICAL TEST, MEASUREMENT TECHNOLOGY, AND EQUIPMENT |
卷号 | 9684 |
会议日期 | 2016-04-26 |
会议地点 | Suzhou, PEOPLES R CHINA |
出版地 | BELLINGHAM |
出版者 | SPIE-INT SOC OPTICAL ENGINEERING |
产权排序 | 1 |
摘要 | The increased sensitivity of space-based sensors has imposed greater stray light performance goals on telescope design. To meet the demand, a stray light test station for measuring point source transmission (PST) has been built with a lower threshold and higher accuracy. The station is nearly all black with dimensions of 28m long by 8m wide by 9m high. it is coupled with a double cylindrical chamber that reflects the specular light away from the instrument under test. The chamber is a Class 6 cleanroom. The station will allow measuring the instruments with up to a 1 meters diameter, and to perform these measurements at visible and infrared wavelengths. The instrument under test will allow to scan at azimuth angles +/-110 degrees, and at elevation +/-15 degrees. The tests were performed to estimate stray light characteristics of two optical instruments. Test results demonstrated PST performance below 1x10(-7) at visible wavelengths, and 1x10(-6) at infrared wavelengths. |
关键词 | Stray Light Point Source Transmission Double Cylindrical Chamber Cleanroom |
学科领域 | Materials Science, Characterization & Testing |
作者部门 | 空间光学应用研究室 |
DOI | 10.1117/12.2243405 |
收录类别 | EI ; ISTP |
ISBN号 | 978-1-62841-919-1 |
语种 | 英语 |
ISSN号 | 0277-786X |
引用统计 | |
文献类型 | 会议论文 |
条目标识符 | http://ir.opt.ac.cn/handle/181661/28455 |
专题 | 空间光学技术研究室 |
通讯作者 | Chen, QF (reprint author), Chinese Acad Sci, Xian Inst Opt & Precis Mech, Xian 710119, Peoples R China. |
作者单位 | 1.Chinese Acad Sci, Xian Inst Opt & Precis Mech, Xian 710119, Peoples R China 2.Chinese Acad Sci, Shanghai Inst Tech Phys, Shanghai 200083, Peoples R China |
推荐引用方式 GB/T 7714 | Chen, Qinfang,Ma, Zhen,Li, Xinyao,et al. Stray Light Measurement for Point Source Transmittance of Space Optical Systems[C]. BELLINGHAM:SPIE-INT SOC OPTICAL ENGINEERING,2016. |
条目包含的文件 | ||||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | ||
Stray Light Measurem(685KB) | 会议论文 | 限制开放 | CC BY-NC-SA | 请求全文 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。