OPT OpenIR  > 空间光学技术研究室
Stray Light Measurement for Point Source Transmittance of Space Optical Systems
Chen, Qinfang1; Ma, Zhen1; Li, Xinyao2; Pang, Zhihai1; Xu, Liang1; Li, Zhaohui1; Chen, QF (reprint author), Chinese Acad Sci, Xian Inst Opt & Precis Mech, Xian 710119, Peoples R China.
2016
会议名称8th International Symposium on Advanced Optical Manufacturing and Testing Technology (AOMATT) - Optical Test, Measurement Technology, and Equipment
会议录名称8TH INTERNATIONAL SYMPOSIUM ON ADVANCED OPTICAL MANUFACTURING AND TESTING TECHNOLOGY: OPTICAL TEST, MEASUREMENT TECHNOLOGY, AND EQUIPMENT
卷号9684
会议日期2016-04-26
会议地点Suzhou, PEOPLES R CHINA
出版地BELLINGHAM
出版者SPIE-INT SOC OPTICAL ENGINEERING
产权排序1
摘要

The increased sensitivity of space-based sensors has imposed greater stray light performance goals on telescope design. To meet the demand, a stray light test station for measuring point source transmission (PST) has been built with a lower threshold and higher accuracy. The station is nearly all black with dimensions of 28m long by 8m wide by 9m high. it is coupled with a double cylindrical chamber that reflects the specular light away from the instrument under test. The chamber is a Class 6 cleanroom. The station will allow measuring the instruments with up to a 1 meters diameter, and to perform these measurements at visible and infrared wavelengths. The instrument under test will allow to scan at azimuth angles +/-110 degrees, and at elevation +/-15 degrees. The tests were performed to estimate stray light characteristics of two optical instruments. Test results demonstrated PST performance below 1x10(-7) at visible wavelengths, and 1x10(-6) at infrared wavelengths.

关键词Stray Light Point Source Transmission Double Cylindrical Chamber Cleanroom
学科领域Materials Science, Characterization & Testing
作者部门空间光学应用研究室
DOI10.1117/12.2243405
收录类别EI ; ISTP
ISBN号978-1-62841-919-1
语种英语
ISSN号0277-786X
引用统计
被引频次:3[WOS]   [WOS记录]     [WOS相关记录]
文献类型会议论文
条目标识符http://ir.opt.ac.cn/handle/181661/28455
专题空间光学技术研究室
通讯作者Chen, QF (reprint author), Chinese Acad Sci, Xian Inst Opt & Precis Mech, Xian 710119, Peoples R China.
作者单位1.Chinese Acad Sci, Xian Inst Opt & Precis Mech, Xian 710119, Peoples R China
2.Chinese Acad Sci, Shanghai Inst Tech Phys, Shanghai 200083, Peoples R China
推荐引用方式
GB/T 7714
Chen, Qinfang,Ma, Zhen,Li, Xinyao,et al. Stray Light Measurement for Point Source Transmittance of Space Optical Systems[C]. BELLINGHAM:SPIE-INT SOC OPTICAL ENGINEERING,2016.
条目包含的文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Stray Light Measurem(685KB)会议论文 限制开放CC BY-NC-SA请求全文
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Chen, Qinfang]的文章
[Ma, Zhen]的文章
[Li, Xinyao]的文章
百度学术
百度学术中相似的文章
[Chen, Qinfang]的文章
[Ma, Zhen]的文章
[Li, Xinyao]的文章
必应学术
必应学术中相似的文章
[Chen, Qinfang]的文章
[Ma, Zhen]的文章
[Li, Xinyao]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。