Study of a symmetrically structured SPR sensor and its dual-wavelength differential method | |
Yang, Hai-ma1,2,3; Ma, Cai-wen1; Wang, Jian-yu2; Liu, Jin4; Chen, Bao-xue3; Yang, HM | |
作者部门 | 光电测量技术实验室 |
2016 | |
发表期刊 | JOURNAL OF MODERN OPTICS |
ISSN | 0950-0340 |
卷号 | 63期号:2页码:85-91 |
产权排序 | 1 |
摘要 | This study investigates a novel structure for surface plasmon resonance sensing and its dual-wavelength differential method. The surface plasmon wave is excited by a planar waveguide, which is prepared through the ion-exchange method. The distribution of refractive indices is fitted by the Fermi function. The sensing structure is based on a symmetric structure with a metal layer, a measured medium, and another metal layer. The condition for refractive index matching changes with the thicknesses of test samples, thus the test range can be adjusted using this structure. Given two appropriate wavelengths lambda(1) and lambda(2) for detection by the intensity method and an increase in the refractive index, the intensity variety at lambda(1) can be positive, whereas that at lambda(2) can be negative. When the refractive indices are determined based on differential values, sensitivity is improved. Solutions with refractive index values ranging from 1.33 to 1.428 are detected in the experiments using the single-wavelength method and the dual-wavelength differential method. Results show that the differential detection method enhances the adjustability and sensitivity of the SPR sensor in combination with a symmetric structure. |
文章类型 | Article |
关键词 | Symmetric Structure Surface Plasmon Resonance Planar Waveguide Fermi Function |
学科领域 | Optics |
WOS标题词 | Science & Technology ; Physical Sciences |
DOI | 10.1080/09500340.2015.1066455 |
收录类别 | SCI ; EI |
关键词[WOS] | OPTICAL WAVE-GUIDE ; BIOSENSORS |
语种 | 英语 |
WOS研究方向 | Optics |
项目资助者 | National Natural Science Foundation of China(61302181) ; Natural Science Foundation of Shanghai(14ZR1418400) ; Innovation Foundation of Shanghai Education Commission(13YZ111) |
WOS类目 | Optics |
WOS记录号 | WOS:000367159300001 |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | http://ir.opt.ac.cn/handle/181661/27340 |
专题 | 光电跟踪与测量技术研究室 |
通讯作者 | Yang, HM |
作者单位 | 1.Chinese Acad Sci, Xian Inst Opt & Precis Mech, Xian, Peoples R China 2.Univ Chinese Acad Sci, Beijing, Peoples R China 3.Univ Shanghai Sci & Technol, Sch Opt Elect & Comp Engn, Shanghai, Peoples R China 4.Shanghai Univ Engn Sci, Coll Elect & Elect Engn, Shanghai, Peoples R China |
推荐引用方式 GB/T 7714 | Yang, Hai-ma,Ma, Cai-wen,Wang, Jian-yu,et al. Study of a symmetrically structured SPR sensor and its dual-wavelength differential method[J]. JOURNAL OF MODERN OPTICS,2016,63(2):85-91. |
APA | Yang, Hai-ma,Ma, Cai-wen,Wang, Jian-yu,Liu, Jin,Chen, Bao-xue,&Yang, HM.(2016).Study of a symmetrically structured SPR sensor and its dual-wavelength differential method.JOURNAL OF MODERN OPTICS,63(2),85-91. |
MLA | Yang, Hai-ma,et al."Study of a symmetrically structured SPR sensor and its dual-wavelength differential method".JOURNAL OF MODERN OPTICS 63.2(2016):85-91. |