Fluorescence X-ray source used for calibrating the detector of X-ray navigation | |
其他题名 | 标定脉冲星导航探测器的荧光X射线光源 |
Dai Jin-Fei1,2; Zhao Bao-Sheng1![]() ![]() ![]() ![]() | |
2015-07-20 | |
发表期刊 | ACTA PHYSICA SINICA
![]() |
卷号 | 64期号:14页码:426-431 |
摘要 | Lots of research work on the X-ray pulsar navigation detector has been carried out, but the rigorous quantitative calibration results of these detectors have never been given out. In order to further promote the research process in X-ray pulsar navigation field, a kind of high-precision X-ray source which could be tunable in energy distribution and photon flux is necessary. A new method has been proposed to generate such an X-ray source, in which a conventional X-ray tube which is called the original level tube is used to excite a special fluorescence target to generate fluorescence X-ray source. Firstly, the primary experiment system is built, with which the intensity of the fluorescence X-ray source is measured in atmospheric environment. The result indicates that the fluorescence X-ray source can be implemented in vacuum system to calibrate the detectors. Then an integral fluorescence X-ray source is fabricated which can be used in vacuum system and its intensity is measured under the condition of D-x = 300 cm and I-a = 200 mu A. The photo fluxes are obtained to be 19.57 phs/s at 4.51 keV, 25.22 phs/s at 5.41 keV, and 33.27 phs/s at 8.05 keV. These data demonstrate the correctness of our method and that this new fluorescence X-ray source can be used to calibrate the x-ray pulsar navigation detector. |
文章类型 | Article |
关键词 | X-ray Pulsar Navigation Fluorescence X-ray Source Detector Calibration |
WOS标题词 | Science & Technology ; Physical Sciences |
DOI | 10.7498/aps.64.149701 |
收录类别 | SCI ; EI |
语种 | 中文 |
WOS研究方向 | Physics |
WOS类目 | Physics, Multidisciplinary |
WOS记录号 | WOS:000362976400055 |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | http://ir.opt.ac.cn/handle/181661/25500 |
专题 | 光电子学研究室 |
作者单位 | 1.Chinese Acad Sci, Xian Inst Opt & Precis Mech, State Key Lab Transent Opt & Photon, Xian 710119, Peoples R China 2.Univ Chinese Acad Sci, Beijing 100084, Peoples R China |
推荐引用方式 GB/T 7714 | Dai Jin-Fei,Zhao Bao-Sheng,Sheng Li-Zhi,et al. Fluorescence X-ray source used for calibrating the detector of X-ray navigation[J]. ACTA PHYSICA SINICA,2015,64(14):426-431. |
APA | Dai Jin-Fei.,Zhao Bao-Sheng.,Sheng Li-Zhi.,Zhou Yan-Nan.,Chen Chen.,...&Li Lin-Sen.(2015).Fluorescence X-ray source used for calibrating the detector of X-ray navigation.ACTA PHYSICA SINICA,64(14),426-431. |
MLA | Dai Jin-Fei,et al."Fluorescence X-ray source used for calibrating the detector of X-ray navigation".ACTA PHYSICA SINICA 64.14(2015):426-431. |
条目包含的文件 | ||||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | ||
标定脉冲星导航探测器的荧光X射线光源.p(619KB) | 期刊论文 | 出版稿 | 限制开放 | CC BY-NC-SA | 请求全文 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论