OPT OpenIR  > 瞬态光学研究室
Video-rate wide-field coherent anti-Stokes Raman scattering microscopy with collinear nonphase-matching illumination
Lei, Ming1,2; Winterhalder, Martin1; Selm, Romedi1; Zumbusch, Andreas1
作者部门瞬态光学国家重点实验室
2011-02-01
发表期刊JOURNAL OF BIOMEDICAL OPTICS
ISSN1083-3668
卷号16期号:2页码:21102
摘要A simple scheme for video-rate wide-field coherent anti-Stokes Raman scattering (CARS) microscopy is presented. The method is based on collinear nonphase-matching illumination. The mechanisms leading to CARS signal generation are investigated. We find that refraction-mediated phase-matching is the main effect. Video-rate wide-field CARS microscopy of polystyrene beads and CARS wide-field images of C. elegans embryos are shown, and the capabilities and the limitations of the scheme are discussed. (C) 2011 Society of Photo-Optical Instrumentation Engineers (SPIE). [DOI:10.1117/1.3533707]
文章类型Article
关键词Coherent Anti-stokes Raman Scattering Microscopy Wide Field Video-rate
学科领域Biochemical Research Methods
WOS标题词Science & Technology ; Life Sciences & Biomedicine ; Physical Sciences
DOI10.1117/1.3533707
收录类别SCI ; EI
关键词[WOS]CARS-MICROSCOPY
语种英语
WOS研究方向Biochemistry & Molecular Biology ; Optics ; Radiology, Nuclear Medicine & Medical Imaging
WOS类目Biochemical Research Methods ; Optics ; Radiology, Nuclear Medicine & Medical Imaging
WOS记录号WOS:000288939200009
引用统计
被引频次:18[WOS]   [WOS记录]     [WOS相关记录]
文献类型期刊论文
条目标识符http://ir.opt.ac.cn/handle/181661/11381
专题瞬态光学研究室
作者单位1.Univ Konstanz, Dept Chem, D-78457 Constance, Germany
2.Chinese Acad Sci, Xian Inst Opt & Precis Mech, State Key Lab Transient Opt & Photon, Xian 710119, Peoples R China
推荐引用方式
GB/T 7714
Lei, Ming,Winterhalder, Martin,Selm, Romedi,et al. Video-rate wide-field coherent anti-Stokes Raman scattering microscopy with collinear nonphase-matching illumination[J]. JOURNAL OF BIOMEDICAL OPTICS,2011,16(2):21102.
APA Lei, Ming,Winterhalder, Martin,Selm, Romedi,&Zumbusch, Andreas.(2011).Video-rate wide-field coherent anti-Stokes Raman scattering microscopy with collinear nonphase-matching illumination.JOURNAL OF BIOMEDICAL OPTICS,16(2),21102.
MLA Lei, Ming,et al."Video-rate wide-field coherent anti-Stokes Raman scattering microscopy with collinear nonphase-matching illumination".JOURNAL OF BIOMEDICAL OPTICS 16.2(2011):21102.
条目包含的文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Video-rate wide-fiel(324KB)期刊论文出版稿限制开放CC BY-NC-SA请求全文
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Lei, Ming]的文章
[Winterhalder, Martin]的文章
[Selm, Romedi]的文章
百度学术
百度学术中相似的文章
[Lei, Ming]的文章
[Winterhalder, Martin]的文章
[Selm, Romedi]的文章
必应学术
必应学术中相似的文章
[Lei, Ming]的文章
[Winterhalder, Martin]的文章
[Selm, Romedi]的文章
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。