Analysis of corrected Cerenkov emission during electron radiotherapy by Monte Carlo method | |
Li, Yi1,2,4; Liu, Hongjun1,3; Huang, Nan1; Wang, Zhaolu1; Zhang, Chunmin2 | |
作者部门 | 瞬态光学研究室 |
2021-02 | |
发表期刊 | Applied Radiation and Isotopes |
ISSN | 09698043;18729800 |
卷号 | 168 |
产权排序 | 1 |
摘要 | Cerenkov emission during electron radiotherapy had been emerging as a new dose assessment approach for clinical radiotherapy and could be imaged through a standard commercial camera. The purpose of this work aimed to study the accuracy of corrected Cerenkov emission method during electron radiotherapy by Monte Carlo (MC) method. GAMOS MC software was used to model the physics of electron therapy and calculated dose and Cerenkov photon distribution in water phantom. Compared to ionization chamber and diode measurement, MC simulated dose discrepancy was less than 1% in percentage depth dose (PDD) curves and less than. 2% in crossline profile curves, which was acceptable for clinical criterion. Compared to ionization chamber dose measurement, MC simulated Cerenkov discrepancy was less than 2% in crossline profile distribution, which was acceptable for clinical criterion. However, the Cerenkov PDD curves tended to overestimate the dose at the build-up region and underestimate the dose at the remaining attenuation region. After increasing the Cerenkov distribution depth to 2–3 mm, the discrepancy became well within 1% at the remaining attenuation region, which was acceptable for clinical criterion. Therefore, corrected Cerenkov emission could be used to assess PDD accuracy and crossline profile accuracy during electron radiotherapy. © 2020 Elsevier Ltd |
关键词 | Corrected cerenkov emission Analysis Electron radiotherapy Monte Carlo |
DOI | 10.1016/j.apradiso.2020.109481 |
收录类别 | SCI ; EI |
语种 | 英语 |
WOS记录号 | WOS:000605532900026 |
出版者 | Elsevier Ltd |
EI入藏号 | 20204409417426 |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | http://ir.opt.ac.cn/handle/181661/93771 |
专题 | 瞬态光学研究室 |
通讯作者 | Liu, Hongjun; Zhang, Chunmin |
作者单位 | 1.State Key Laboratory of Transient Optics and Photonics, Xi'an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi'an; 710119, China; 2.School of Physics, Xi'an Jiaotong University, Xi'an; 710049, China; 3.Collaborative Innovation Center of Extreme Optics, Shanxi University, Taiyuan; 030006, China; 4.University of Chinese Academy of Science, Beijing; 100084, China |
推荐引用方式 GB/T 7714 | Li, Yi,Liu, Hongjun,Huang, Nan,et al. Analysis of corrected Cerenkov emission during electron radiotherapy by Monte Carlo method[J]. Applied Radiation and Isotopes,2021,168. |
APA | Li, Yi,Liu, Hongjun,Huang, Nan,Wang, Zhaolu,&Zhang, Chunmin.(2021).Analysis of corrected Cerenkov emission during electron radiotherapy by Monte Carlo method.Applied Radiation and Isotopes,168. |
MLA | Li, Yi,et al."Analysis of corrected Cerenkov emission during electron radiotherapy by Monte Carlo method".Applied Radiation and Isotopes 168(2021). |
条目包含的文件 | ||||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | ||
Analysis of correcte(10844KB) | 期刊论文 | 出版稿 | 限制开放 | CC BY-NC-SA | 请求全文 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论