Experimental demonstration of wave-front coded imaging with a very low response of the modulation transfer function at the Nyquist frequency | |
Zhao, Hui1; Mi, Jiao1,2; Yu, Congcong1,2; Ge, Rui1,2; Fan, Xuewu1 | |
作者部门 | 空间光学技术研究室 |
2019-12-10 | |
发表期刊 | Applied Optics |
ISSN | 1559128X;21553165 |
卷号 | 58期号:35页码:9562-9569 |
产权排序 | 1 |
摘要 | Wave-front coding (WFC) is a well-known technique that can be used to extend the depth of field (DOF) of incoherent imaging systems. The phase masks make the optical transfer function drop significantly, and digital restoration must be used to obtain a clear image with a largely extended DOF. According to the existing literature, in order to obtain satisfactory restoration results, the optical modulation transfer function (MTF) at the Nyquist frequency is required to be bigger than 0.1, which has already become a popularly accepted design constraint. However, according to our experimental research reported in this paper, this requirement is overly strict. By assembling one already fabricated WFC lens and another camera having physically higher resolution, the MTF of the newly assembled WFC system used in the experimentation has quite a low response at its Nyquist frequency. The experimental results demonstrate that when the optical MTF value at the Nyquist frequency reaches the minimum value of about 0.05, visually satisfactory restoration results can still be obtained as long as the MTF is optimized to be highly insensitive to defocus and the corresponding SNR of the coded intermediate images goes beyond 20 dB at the same time. The experimental results indicate that the overly strict constraint could be alleviated while designing a WFC system. © 2019 Optical Society of America. |
DOI | 10.1364/AO.58.009562 |
收录类别 | SCI ; EI |
语种 | 英语 |
WOS记录号 | WOS:000502086200010 |
出版者 | OSA - The Optical Society |
EI入藏号 | 20195007824196 |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | http://ir.opt.ac.cn/handle/181661/32075 |
专题 | 空间光学技术研究室 |
通讯作者 | Zhao, Hui |
作者单位 | 1.Space Optics Lab, Xi’an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi’an; 710019, China; 2.University of Chinese Academy of Sciences, Beijing; 100049, China |
推荐引用方式 GB/T 7714 | Zhao, Hui,Mi, Jiao,Yu, Congcong,et al. Experimental demonstration of wave-front coded imaging with a very low response of the modulation transfer function at the Nyquist frequency[J]. Applied Optics,2019,58(35):9562-9569. |
APA | Zhao, Hui,Mi, Jiao,Yu, Congcong,Ge, Rui,&Fan, Xuewu.(2019).Experimental demonstration of wave-front coded imaging with a very low response of the modulation transfer function at the Nyquist frequency.Applied Optics,58(35),9562-9569. |
MLA | Zhao, Hui,et al."Experimental demonstration of wave-front coded imaging with a very low response of the modulation transfer function at the Nyquist frequency".Applied Optics 58.35(2019):9562-9569. |
条目包含的文件 | ||||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | ||
Experimental demonst(1978KB) | 期刊论文 | 出版稿 | 限制开放 | CC BY-NC-SA | 请求全文 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论