OPT OpenIR  > 检测技术研究中心
Analysis of Attitude Measurement Accuracy and Indoor Evaluation Method of Photoelectric Theodolite
Alternative Title光电经纬仪姿态测量精度分析及室内评价方法
Zhao, Huaixue1; Tian, Liude1,2; Zhao, Jianke1; Xue, Xun1; Pan, Liang1; Wang, Tao1
Department检测技术研究中心
2018-01-10
Source PublicationGuangxue Xuebao/Acta Optica Sinica
ISSN02532239
Volume38Issue:1
Contribution Rank1
Abstract

In order to realize indoor test and evaluation of attitude measurement accuracy of photoelectric theodolite, an attitude measurement method of photoelectric theodolite is developed. Based on Monte Carlo method, the error sources are analyzed. Main influencing factors on attitude measurement accuracy are obtained, and a detection method for indoor attitude measurement accuracy is proposed. Based on outfield theoretical trajectory, target attitude and measuring station coordinates, the original data of attitude measurement is obtained by inverse attitude measurement theory. The original data is input into the photoelectric theodolite to obtain the test target attitude. The theoretical target attitude and the test target attitude are compared, and the attitude measurement accuracy of the attitude measurement equipment is obtained. According to this method, the attitude measurement accuracy of a certain type of attitude measurement equipment is tested. Attitude measurement accuracy of the attitude measurement equipment can be obtained by experiments. The heading angle measurement error is not larger than 1.9°, pitch angle measurement error is not larger than 0.4°. © 2018, Chinese Lasers Press. All right reserved.

DOI10.3788/AOS201838.0112004
Indexed ByEI ; CSCD
Language中文
CSCD IDCSCD:6175638
EI Accession Number20181705054807
Citation statistics
Cited Times:1[CSCD]   [CSCD Record]
Document Type期刊论文
Identifierhttp://ir.opt.ac.cn/handle/181661/30070
Collection检测技术研究中心
Affiliation1.Xi'an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi'an; Shaanxi; 710119, China
2.University of Chinese Academy of Sciences, Beijing; 100049, China
Recommended Citation
GB/T 7714
Zhao, Huaixue,Tian, Liude,Zhao, Jianke,et al. Analysis of Attitude Measurement Accuracy and Indoor Evaluation Method of Photoelectric Theodolite[J]. Guangxue Xuebao/Acta Optica Sinica,2018,38(1).
APA Zhao, Huaixue,Tian, Liude,Zhao, Jianke,Xue, Xun,Pan, Liang,&Wang, Tao.(2018).Analysis of Attitude Measurement Accuracy and Indoor Evaluation Method of Photoelectric Theodolite.Guangxue Xuebao/Acta Optica Sinica,38(1).
MLA Zhao, Huaixue,et al."Analysis of Attitude Measurement Accuracy and Indoor Evaluation Method of Photoelectric Theodolite".Guangxue Xuebao/Acta Optica Sinica 38.1(2018).
Files in This Item:
File Name/Size DocType Version Access License
Analysis of Attitude(5572KB)期刊论文作者接受稿开放获取CC BY-NC-SAView Application Full Text
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Zhao, Huaixue]'s Articles
[Tian, Liude]'s Articles
[Zhao, Jianke]'s Articles
Baidu academic
Similar articles in Baidu academic
[Zhao, Huaixue]'s Articles
[Tian, Liude]'s Articles
[Zhao, Jianke]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Zhao, Huaixue]'s Articles
[Tian, Liude]'s Articles
[Zhao, Jianke]'s Articles
Terms of Use
No data!
Social Bookmark/Share
File name: Analysis of Attitude Measurement Accuracy and Indoor Evaluation Method of Photoelectric Theodolite.pdf
Format: Adobe PDF
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.